Vertical double air duct air sleeve with turbine centrifugal forced air supply, Temperature Uniformity of +/- 2.5%; Speed control fan supports lightweight and small Sample Handling to ensure long-term stable operation of the equipment.
Category : Drying Oven
Brand : BenTing
SKU : NB028575
Service :The delivery and service By NBCLab.Com
BENTING CBX65BE sterilization box is a vertical dual air duct forced convection sterilizing equipment. It adopts stainless steel studio and Cold rolled steel plate outer box, and is equipped with LCD dual row PID temperature control system to achieve efficient and safe sterilization function. The product has a convenient operation mode such as fixed value operation, timing operation and automatic stop, which is suitable for sterilizing all kinds of lightweight, fine and powdery samples.
1. Fast, safe and reliable sterilizing performance 2. Convenient operation, support fixed-value operation, regular operation and automatic stop 3. Dedicated function keys to achieve temperature setting 4. Auxiliary menu provides over-rise alarm, deviation correction and menu lock function 5. Vertical double air duct air sleeve design, turbine centrifugal forced air supply, uniform temperature distribution 6. The speed-regulating fan supports the use of lightweight, fine, and powdery samples 7. Forced fan cooling intake structure to ensure that the fan operating temperature is lower than 50 ° C and prolong the service life 8. LCD multi-data full-screen operation display, with power outage memory and power outage compensation functions 9. Equipped with overlift preventer to enhance safety
The sterilization box uses a stainless steel heating tube to generate heat through the forced convection method of double air ducts, and the turbine centrifugal fan forces the air to ensure the uniform distribution of the temperature in the studio. The PID temperature control system is used to precisely adjust the temperature to realize the sterilizing process from room temperature + 10 ° C to 300 ° C, and the speed regulating fan is used to adapt to the sterilizing needs of different samples.
Laboratory sterilizing, Medical equipment disinfection, Research Sample Handling, Industrial material disinfection
Overlift preventer safety standard, PID temperature control standard
1. Connect the AC220V power supply 2. Set the target temperature by tapping the four buttons 3. Select fixed-value operation or timing operation mode 4. Set the timing time (0-9999 minutes) 5. Start running and the device will automatically stop 6. Use the auxiliary menu for deviation correction or menu lock operation
• Power frequency is AC220V before use • Maximum single shelf load does not exceed 15kg • Do not block the top φ 28mm exhaust port during operation • Regularly check the overlift preventer function • The fan temperature may rise when the equipment is working, but it should be kept below 50 ° C • The device has a memory function after a power outage, and the operation status needs to be confirmed after the power supply is restored • Do not modify the temperature setting while the device is running Keep the Studio Clean to Avoid Temperature Uniformity
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.