Please contact customer service
Shelf heating independent, temperature uniformity of +/- 0.5 ℃, maximum temperature of 250 ℃. Equipped with bulletproof tempered Glass observation window, box door sealing adjustable to ensure high Vacuum Level, support single double-decked heating mode and 30-stage 40-step program operation.
Category : Drying Oven
Brand : TaiSiTe
SKU : NB029115
Service :The delivery and service By NBCLab.Com
TAISITE DZ91T Vacuum oven is a drying equipment using independent Shelf heating. It is equipped with 5.0 inch LCD Touchscreen, supports multi-stage PID full temperature program temperature control, accurate and reliable temperature control, uniform and stable heating, can store materials in vacuum or inert gas environment, heating and drying.
1. Adopt independent Shelf heating, heating uniform and stable, Shelf removable, easy to install. 2.5.0 inch LCD Touchscreen, supports multi-stage PID full temperature section program temperature control, accurate and reliable temperature control. 3. Equipped with bulletproof tempered Glass observation window, it is convenient to observe the objects in the work room, and can be filled with inert gas into the interior. 4. The box door is closed and elastic and adjustable, and the integrally formed synthetic silicon door sealing ring is used to ensure that the box maintains a high Vacuum Level. 5. It can work in an oxygen-free or inert gas environment to effectively prevent material oxidation. 6. Heating mode is flexible, optional single-layer or double-decked heating mode. 7. The controller supports two operation modes: fixed-value operation and program operation. 8. When running at a fixed value, the heating rate can be set, and three timing methods of start timing, thermostatic timing, and shutdown timing are supported. 9. When the program is running, 30 programs can be set, each corresponding to 40 steps, which can be flexibly invoked, edited (insert, delete steps), and set the temperature, time, and jump of each step according to the experimental requirements. 10. With deviation correction, power outage compensation, real-time Linear dispersion recording and other additional functions.
The Vacuum oven extracts air from the working room through a vacuum pump to create a low-oxygen or vacuum environment, and at the same time heats the material through an independent Shelf heater. Under the program control, the temperature and time are precisely controlled, so that the moisture or solvent in the material is quickly evaporated at low temperature and extracted, so as to achieve efficient drying, and can be filled with inert gas in the process to prevent oxidation.
Material drying, sample storage, heat treatment, experimental research, electronic component processing, chemical material processing, pharmaceutical industry, R & D institutions
The data did not mention specific compliance criteria.
1. Placement of materials: Place the materials to be processed on a detachable independent Shelf. 2. Close the door: close the door and adjust the tightness to ensure sealing. 3. Setting parameters: Select the running mode (fixed value or program) on the 5.0-inch LCD Touchscreen, and set the corresponding temperature, time, heating rate and other parameters. 4. Start the vacuum: Connect the vacuum pump and start the vacuum procedure to achieve the required Vacuum Level (< 133Pa). 5. Start running: Start the heating and control program, and the equipment will run automatically according to the set program. 6. Process observation: Monitor internal conditions through bulletproof tempered Glass observation windows. 7. End the pickup: After the program runs, break the vacuum first, and then open the box door to take out the material.
• Please ensure that the equipment is well grounded and powered according to the Rated voltage (220V 50Hz). • When placing materials, the maximum load of the single-layer shelf should not exceed 15kg, and the airflow channel in the working room should not be blocked. • Before vacuuming, make sure the door is closed and the sealing ring is intact to ensure Vacuum Level. • During the operation of the equipment, do not open and close the box door frequently, so as not to affect the temperature and Vacuum Level in the box. • When filling with inert gas, confirm that the pipeline is connected correctly and control the appropriate Gas flow rate and pressure. • Program settings, pay attention to the temperature setting range (RT + 10~ 250 ℃) to avoid overrun. • Equipment is equipped with safety devices such as independent thermostats, please do not disassemble or Shielding at will. • When cleaning the equipment, please cut off the power first and wipe it with a soft cloth to avoid the use of corrosion cleaners. • If not used for a long time, please clean the inside of the equipment and keep it drying.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.