With three-sided lighting six-level adjustable, Illumrination degree 0-15000Lx; 30-segment LCD program control, support setting, timing and program operation; equipped with turbine centrifugal forced air supply, Temperature uniformity +/- 1.5 ℃.
Category : Incubator
Brand : TaiSiTe
SKU : NB029168
Service :The delivery and service By NBCLab.Com
TAISITE GZX250E light Chamber is a device with forced convection thermostatic mode and three-sided lighting function. Its Temperature range is 0~ 65 ° C without humidification, 10~ 65 ° C with humidification, and the content product is 250L. The product adopts 30-segment LCD program control, supports fixed-value operation, timing operation, program operation and other modes, and has a number of safety and intelligent functions.
1. Adopt stable high luminous flux Illuminant, provide three-sided light, Illumrination degree 0-15000Lx six-level adjustable to ensure Illuminant stability. 2. Adopt 30-segment LCD program control, support repeated step-by-step, step-by-step operation, easy operation, support fixed-value operation, regular operation, and automatic stop. 3. Equipped with special function keys for temperature setting, and has auxiliary menus, which can realize functions such as over-rise alarm, deviation correction, and menu lock. 4. Adopt turbine centrifugal forced air supply to make the temperature more uniform. With power-off protection, parameter memory, and call recovery functions. 5. With loop self-diagnosis, Sensor fault alarm, upper and lower limit over-temperature alarm function. 6. With intelligent defrosting, monitoring and timekeeping functions, using brand Compressors. 7. With multiple Safety protection functions such as over-lift prevention and overload protection. 8. The liner adopts mirror stainless steel plate, the outer box is Cold rolled steel plate surface resistance painting, the heat insulation material is polyurethane, and the heating device is stainless steel heating pipe.
The light Chamber ensures uniform temperature in the box through a forced convection system (turbine centrifugal forced air supply). Temperature control is realized by a 30-segment LCD program controller, which monitors the temperature in the box through a PT100 temperature sensor, and controls the stainless steel heating pipe and air-cooled closed Compressor (refrigerant R134A) for heating or cooling to maintain the set temperature environment. The lighting system provides stable and adjustable three-sided lighting to meet the lighting conditions required by foster. The equipment has automatic defrosting, programmed operation and multiple Safety protection mechanisms.
Biological fostering, plant growth experiments, seed germination, microbial research
No specific compliance criteria were mentioned in the data.
1. Turn on the power supply (AC 220V). 2. Set the temperature, Illumrination degree and running program by tapping the button (support 30 program settings). 3. Select the operation mode, such as fixed-value operation, regular operation, or program operation. 4. Set the timer time (0~ 99.9 hours, 30 segments can be set). 5. Start the device and start running. 6. After the operation is completed, the device can be automatically stopped. 7. The measured temperature can be viewed in the upper part of the LCD screen, and the set temperature can be viewed in the lower part.
* The power supply of the device is AC220V/4.5A 50/60Hz, please ensure that the power supply matches. * Temperature range is 0~ 65 ℃ without humidification, 10~ 65 ℃ with humidification, please do not use beyond the range. * Single Shelf (shelf) maximum load-bearing 15kg, do not overload. The equipment has functions such as over-lift alarm and overload protection. Please check and troubleshoot in time when alarming. The device has a menu button lock function to prevent incorrect operation. The equipment is equipped with power outage compensation and memory functions, and can resume operation after an incoming call, but it is still necessary to pay attention to the impact of power outage during operation. Do not cover the rear panel of the device for easy observation and maintenance. The equipment is equipped with automatic defrosting, eliminating the need for manual operation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.