Please contact customer service
The highest temperature can reach 1200 ℃, Furnace volume 16L, vacuum forming polycrystalline mullite fiber Furnace insulation, special alloy heating wire three-sided heating to ensure Temperature uniformity, with multiple Safety protection such as door power failure and over-rise alarm.
Category : Muffle Furnace
Brand : TaiSiTe
SKU : NB029212
Service :The delivery and service By NBCLab.Com
TAISITE MFLC-16/12T ceramic muffle furnace is a laboratory heating equipment with a maximum temperature of 1200 ° C. It adopts an integrated lightweight and compact design, furnace volume is 16L, Heating power is 6KW, using microcomputer PID control, equipped with 7-inch color Touchscreen for programmed temperature control, temperature control accuracy can reach +/- 1 ° C.
1. Integrated lightweight and compact structure. 2. Vacuum forming polycrystalline mullite fiber furnace, good thermal insulation effect. 3. Special nickel-chromium-aluminum alloy heating wire heating on three sides, Temperature uniformity is good. 4. Double shell air insulation, low surface temperature. 5. Equipped with an exhaust device, which is conducive to ashing. 6. High Accuracy Microcomputer Temperature Controller Combined with K-type Thermocouple for accurate temperature control. 7.7 inch color Touchscreen, finger touch light point setting, intuitive operation. 8. With real-time Linear dispersion recording, U disk data export function. 9. Multiple safety designs: door opening and power failure, reset delay, over-rise alarm, menu locking, over-rise prevention, over-current and leakage protection. 10. Parallel side open furnace door design keeps the hot end away from the operator.
The muffle furnace uses microcomputer PID control technology to monitor the temperature in the furnace in real time through K-type Thermocouple and feed back the signal to the controller. The controller precisely adjusts the Power supplied to the nickel-chromium-aluminum alloy heating element according to the deviation of the set temperature and the measured temperature, so as to achieve fast and stable heating and thermostatic. The heating element adopts a three-sided arrangement, combined with the excellent thermal insulation performance of the vacuum-formed polycrystalline mullite fiber furnace, to ensure uniform temperature inside the furnace.
Material ashing, sample sintering, heat treatment, laboratory high temperature experiment
The data did not mention specific compliance criteria.
1. Turn on the power supply and turn on the power switch of the device. 2. On the 7-inch color Touchscreen, set the target temperature, heating program or timing time by tapping the finger. 3. After confirming that the parameters are correct, start the heating procedure. 4. The device runs automatically according to the setting program, and the real-time temperature Linear dispersion can be observed through the screen. 5. After the experiment, wait for the furnace temperature to naturally chill down or cool down according to the program. 6. If you need to export data, you can operate it through the U disk interface. 7. Turn off the power switch and disconnect the power.
The equipment requires an AC220V/27.3A power supply to ensure stable power supply. * When the furnace body is working, the surface may still be hot, do not touch, and pay attention to ventilating. * The device will automatically power off when opening the door. There will be a delay in repowering after closing the furnace door. Please wait. * Do not heat flammable, explosive or toxic gases in the furnace. The maximum temperature in the furnace must not exceed 1200 degrees Celsius. When taking samples, special tools should be used and protective equipment should be worn to prevent burns. Regularly check whether the equipment is properly grounded and whether the overcurrent and leakage protection switch is normal. * The equipment is heavy (gross weight 86kg), so pay attention to safety when moving. When not in use for a long time, please disconnect the power supply.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.