$ 812.00Ex works
Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S., with explosion-proof certification and a variety of output interfaces, support remote monitoring and automatic zero point calibrating.
Category : Gas Detector
Brand : honeyeagle
SKU : NB029880
Service :The delivery and service By NBCLab.Com
HONEYEAGLE HNAG1000-CO online carbon monoxide detector is suitable for real-time and accurate detection of carbon monoxide concentration and leakage in various environments. It adopts imported Electrochemical sensor and microcontroller technology, and has the advantages of fast Response Speed, High Measurement accuracy, Good Stability and Repeatability. Explosion-proof wiring method is suitable for dangerous places, compatible with control alarms, PLC, DCS and other Control systems, support on-site alarm warning, 4-20mA standard signal output and relay switch output, with circuit protection function to prevent instrument damage.
1. Intrinsically safe circuit design, explosion-proof certification, two-level lightning protection, anti-static, anti-high-intensity pulse surge current Impact, High Reliability and Stability. 2. Standard bus RS485 and 4~ 20mA standard signal output simultaneously, optional Frequency output, Hart protocol signal, 1~ 5V output, wireless transmission, support wired or wireless remote real-time monitoring. 3. Compatible with secondary meter, data collection module, PLC, DCS system, can directly drive solenoid valve, fan, alarm and other equipment. 4. Standard infrared remote control, to achieve dangerous situations without opening the lid operation, such as modifying the alarm point, concentration calibrating. 5.2.5 inch high definition color screen display real-time concentration, temperature, Humidity. 6. Automatic zero tracking to prevent drift, temperature compensation, multi-level calibrating, in line with national standards and local Measurement Bureau standards.
Electrochemical sensor and microcontroller technology are used to detect carbon monoxide gas concentration by diffusion Sampling method. Based on the principle of infrared NDIR, the Sensor measures gas concentration in real time and Outputs signal, combined with automatic Zero tracking and temperature compensation technology to ensure Measurement accuracy and Stability.
Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, scientific research, production workshops, Tobacco companies, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, dangerous place safety protection, aerospace, military equipment monitoring
EMI, EMC Standard, National Standard Testing, CMC Measurement Equipment License Certification, GB 3836.1 - 2010, GB 3836.2 - 2010, GB 3836.4 - 2010
1. Use the infrared remote control to operate without opening the lid, such as modifying the alarm point, concentration calibrating, zero calibrating, muffling, restoring factory settings, and entering the menu. 2. View real-time concentration, temperature, Humidity and other parameters through a 2.5-inch high definition color screen. 3. Connect output interfaces (e.g. RS485, 4-20mA) for data transmission and remote monitoring. 4. Drive external devices such as solenoid valves, fans, or alarms as required.
• Ensure that the working Ambient Temperature is in the range of -30~ 50 ℃, and the storage temperature is in the range of -40~ 70 ℃. • Environmental humidity should be maintained at 0~ 95% RH non-condensation state. • Operating Pressure range is 86~ 106kPa. • Avoid use in non-explosion-proof environments to prevent danger. • Periodic calibrating and maintenance to maintain detection accuracy. • Use a DC5V +/- 1% or DC24 +/- 1% power supply to ensure that the current does not exceed 50mA.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.