$ 614.00Ex works
Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with automatic Zero tracking and temperature compensation function, support RS485 and 4-20mA dual signal output, Protection Rating IP66, adapt to -30~ 50 ℃ working environment.
Category : Gas Detector
Brand : honeyeagle
SKU : NB029955
Service :The delivery and service By NBCLab.Com
HONEYEAGLE HNAG1000-NO (0-2000PPM) Nitric Oxide Detector is an online Gas detection device suitable for real-time accurate detection of nitric oxide concentration and leakage in various environments. The product adopts imported Electrochemical sensor and microcontroller technology, which has the advantages of fast Response Speed, High Measurement accuracy, Stability and Repeatability, supports explosion-proof wiring, is compatible with a variety of Control systems, and has on-site alarm and a variety of output functions.
1. Intrinsically safe circuit design, explosion-proof certification, two-level lightning protection, anti-static, anti-high-intensity pulse surge current Impact, High Reliability and Stability. 2. Standard bus RS485 and 4~ 20mA standard signal output at the same time, can choose a variety of signal output mode, support wired or wireless remote real-time monitoring. 3. Compatible with various secondary tables, data collection modules, PLC, DCS systems, can directly drive external devices. 4. Standard infrared remote control to achieve lid-free operation in dangerous situations. 5.2.5 inch high definition color screen display real-time concentration, temperature, Humidity. 6. Automatic zero tracking to prevent drift, temperature compensation, multi-level calibrating, in line with national standards and local Measurement Bureau standards.
Electrochemical sensor is used to detect nitric oxide gas by diffusion Sampling method. Sensor converts gas concentration into electrical signal, which is processed by microcontroller and outputs standard signal to realize real-time concentration measurement and alarm function.
Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, scientific research, production workshops, Tobacco companies, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, dangerous place safety protection, aerospace, military equipment monitoring
EMI, EMC Standard, National Standard Testing, CMC Measurement Equipment License Certification, GB 3836.1 - 2010, GB 3836.2 - 2010, GB 3836.4 - 2010
1. Installation equipment: fixed installation at the detection point. 2. Connect power supply: Connect to DC5V +/- 1% or DC24 +/- 1% power supply. 3. Output configuration: Connect RS485 or 4-20mA output interface as required. 4. Use the infrared remote control to set: modify the alarm point, concentration calibrate, zero calibrate, muffle, restore the factory, and enter the menu. 5. Monitoring display: View real-time concentration, temperature, Humidity and other parameters through a 2.5-inch high definition color screen.
• Working ambient temperature range is -30~ 50 ℃, storage temperature is -40~ 70 ℃, avoid using beyond the range. • Environmental humidity is 0~ 95% RH non-condensation to prevent Humidity from affecting performance. • Operating Pressure should be kept at 86~ 106kPa to ensure measurement accuracy. Equipment Protection Rating is IP66, but should be avoided under extreme conditions. • Sensor service life is 3-5 years, regular inspection and replacement. • Response Time is less than 10 seconds, Warm-Up Time is 10 seconds, and you need to wait for the device to stabilize when using it. • The explosion-proof marking is Ex d IIC T6, which is suitable for use in hazardous locations, but must be operated according to specifications. • Avoid damage to the instrument due to human factors or uncontrollable factors, and pay attention to the circuit protection function during use.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.