$ 630.00Ex works
Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design, support RS485 and 4-20mA dual output, equipped with 2.5 inch color screen display real-time concentration, Temperature Humidity paraMeters.
Category : Gas Detector
Brand : honeyeagle
SKU : NB029962
Service :The delivery and service By NBCLab.Com
HONEYEAGLE Online Ammonia Detector HNAG1000-NH3 (0-1000PPM) is suitable for real-time and accurate detection of ammonia concentration and leakage in various environments. The product adopts imported Electrochemical sensor and microcontroller technology, which has the advantages of fast Response Speed, High Measurement accuracy, Good Stability and Repeatability. Explosion-proof wiring is suitable for hazardous places, compatible with various Control systems, supports on-site alarm and warning, 4-20mA standard signal output and relay switch output.
1. Intrinsically safe circuit design, explosion-proof certification, two-level lightning protection, anti-static, anti-high-intensity pulse surge current Impact, High Reliability and Stability. 2. Standard bus RS485 and 4~ 20mA standard signal output simultaneously, 1 set of relay switch output, optional Frequency output, Hart protocol signal, 1~ 5V output, wireless transmission, support wired or wireless remote real-time monitoring. 3. Compatible with various secondary meters, data collection modules, PLC, DCS systems, can directly drive solenoid valves, fans, alarms and other equipment. 4. Standard infrared remote control, realize the operation without opening the lid in dangerous situations, such as modifying the alarm point, concentration calibrating, etc. 5.2.5 inch high definition color screen display real-time concentration, temperature, Humidity. 6. Automatic zero tracking to prevent drift, temperature compensation, multi-level calibrating, in line with national standards and regional Measurement Bureau standards.
The ammonia gas detector adopts the principle of Electrochemical sensor to detect gas NH3 through diffusion Sampling method. The Sensor converts the gas concentration into an electrical signal, which is processed by the microcontroller and outputs a standard signal. The product has automatic Zero tracking and temperature compensation functions to ensure Measurement accuracy and Stability.
Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, scientific research, production workshops, Tobacco companies, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, dangerous place safety protection, aerospace, military equipment monitoring
EMI, EMC Standard, National Standard Testing, CMC Measurement Equipment License Certification, GB 3836.1 - 2010, GB 3836.2 - 2010, GB 3836.4 - 2010
1. Install the equipment in a fixed position to ensure that the working environment meets the specifications. Connect the power supply and output interface, such as RS485 or 4-20mA signal cable. 3. Use the infrared remote control for initial settings, including alarm point modification, concentration calibrating and zero point calibrating. 4. Start the equipment and start monitoring the ammonia concentration in real time after 10 seconds of preheating. 5. View real-time data through the LCD screen, or receive Output signals from the remote monitoring system.
• Ensure that the working Ambient Temperature is in the range of -30~ 50 ℃, Humidity 0~ 95% RH non-condensation. • Avoid use in environments that exceed specifications to prevent equipment damage. • Use the infrared remote control to operate in dangerous situations and avoid opening the lid to ensure safety. • Periodic calibrating and maintenance to maintain Measurement accuracy and Stability. • Pay attention to explosion-proof and protective requirements during installation, and comply with relevant standards.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.