$ 477.00Ex works
Imported Electrochemical sensor, Response Time less than 10 seconds, accuracy of +/- 2% F.S., with explosion-proof design and a variety of output interfaces, support remote monitoring and Automatic calibration, suitable for hazardous environments.
Category : Gas Detector
Brand : honeyeagle
SKU : NB029977
Service :The delivery and service By NBCLab.Com
HONEYEAGLE HNAG1000-ETO (0-10PPM) ethylene oxide detector is an online Gas detection device for real-time and accurate detection of ethylene oxide gas concentration and leakage in various environments. The instrument adopts imported Electrochemical sensor and microcontroller technology, which has the advantages of fast Response Speed, High Measurement accuracy, Stability and Repeatability. Explosion-proof wiring is suitable for hazardous places and is compatible with a variety of Control systems.
1. Intrinsically safe circuit design, explosion-proof certification, two-level lightning protection, anti-static, anti-high-intensity pulse surge current Impact, High Reliability and Stability. 2. Standard bus RS485 and 4~ 20mA standard signals are output simultaneously, and a variety of output methods can be selected to support wired or wireless remote real-time monitoring. 3. Compatible with various secondary tables, data collection modules, PLC, DCS systems, can directly drive external devices. 4. Standard infrared remote control to achieve lid-free operation in dangerous situations. 5.2.5 inch high definition color screen display real-time concentration, temperature, Humidity. 6. Automatic zero tracking to prevent drift, temperature compensation, multi-level calibrating, in line with national standards and local Measurement Bureau standards.
Electrochemical sensor is used to detect ethylene oxide concentration by diffusion Sampling method. The sensor converts gas concentration into electrical signal, displays real-time value on the screen after processing by microcontroller, and outputs standard signals such as RS485 and 4-20mA to realize concentration monitoring and control.
Petroleum and petrochemical, chemical plants, smelters, steel plants, coal plants, thermal power plants, scientific research, production workshops, Tobacco companies, environment monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, waste treatment plant, tunnel construction, oil pipeline, gas station, underground gas pipeline maintenance, indoor air mass detection, dangerous place safety protection, aerospace, military equipment monitoring
EMI, EMC Standard, National Standard Testing, CMC Measurement Equipment License Certification, GB 3836.1 - 2010, GB 3836.2 - 2010, GB 3836.4 - 2010
1. Installation equipment: fixed installation at the detection point to ensure that the working environment meets the requirements. 2. Connect power supply: Use DC5V or DC24V power supply. 3. Output signal connection: Connect RS485 or 4-20mA output interface as needed. 4. Use the infrared remote control to set: modify the alarm point, concentration calibrating, zero calibrating, muffling, factory recovery and other operations. 5. Monitoring display: View gas concentration, temperature, Humidity and other parameters in real time through a 2.5-inch high definition color screen. 6. Remote monitoring: Optional wireless transmission, upload data to mobile phone or monitoring center.
• Ensure that the working Ambient Temperature is in the range of -30~ 50 ℃, Humidity 0~ 95% RH non-condensation. • Avoid use or storage in an environment beyond the storage temperature of -40~ 70 ° C. • Use the infrared remote control to operate in dangerous situations and avoid opening the lid to reduce the risk. • Periodic calibrating and maintenance to maintain Measurement accuracy and Stability. • Pay attention to explosion-proof signs and Protection Ratings to ensure safe use in applicable hazardous locations. • Output signal connection, follow the relevant electrical standards to prevent man-made damage.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.