Overview
The BOLEL PURIFICATION EQUIPMENT APB-700 clean two-way transfer window is an auxiliary equipment for clean rooms. It is mainly used for the transfer of small items between clean rooms and non-clean areas to reduce the number of times the clean room is opened, thereby minimizing the risk of contamination.
Features
1. The countertop and box are made of stainless steel plate, which is smooth and clean.
2. The doors on both sides are equipped with mechanical interlocking or electronic locking devices, so that the doors on both sides cannot be opened simultaneously.
3. The electronic interlocking transmission window box is equipped with door opening signal indicator lights on both sides to know the opening of the opposite window.
4. The transfer window is equipped with a special sealing strip to ensure airtightness.
5. According to different uses, indoor lamps and sterilization lamps can be added.
6. It can be processed into a self-cleaning clean transfer window or a transfer window of various Specification models according to user requirements.
Principle
The transfer window, through its box structure and the interlocking devices (mechanical or electronic) of the doors on both sides, ensures that the doors of the clean area and the non-clean area cannot be opened at the same time when transferring goods, forming a temporary and controlled transfer channel to maintain the air pressure and cleanliness of the clean room and reduce the entry of external pollution.
Applications
Cleanrooms, biological laboratories, pharmaceutical workshops, electronic dust-free workshops, Food processing clean areas, hospital operating rooms and other places that need to control cleanliness.
Steps
1. Put the items to be delivered into the transfer window and close the side door.
2. Through the interlocking device, the door on the other side can only be opened after the door on the other side is locked.
3. The receiver opens the door from the other side and removes the item.
4. Close the receiving side door and complete the transfer.
Notice
• Before passing items, please make sure the transfer window is clean.
• It is strictly forbidden to force open the doors on both sides at the same time to avoid damage to the interlock device.
• Regularly check whether the sealing strip is in good condition to ensure airtightness.
• According to the needs of use, you can choose to turn on the indoor light or sterilization light function.
• For specific operations, please refer to the product manual or consult a professional.