Overview
LEICI DGB-402F Portable residual chlorine total chlorine tester is a high definition color LCD screen display, built-in residual chlorine and total chlorine Measuring method Portable testing equipment. It has intelligent end point determination, automatic reading, Data storage and transmission functions, suitable for on-site rapid water quality testing.
Features
1. Using 515nm LED Illuminant, long life and high accuracy
2. Measuring method for residual chlorine and total chlorine
3. Intelligent determination of endpoints, support for automatic and continuous readings
4. Set the diluted ratio to automatically calculate the original concentration of the sample
5. Support built-in calibrated Linear dispersion, restore default Linear dispersion and custom (1~ 3 points) calibrated
6. Large data storage capacity (200 sets of residual chlorine/total chlorine each), support access, deletion, transmission and printing
7. Compliant with GLP standards for data traceability
8. Support connecting RS-232 serial printers and PCs (via USB interface)
9. Large-capacity lithium battery power supply, supports PC and mobile power charging
10. Battery level prompt and charging status reminder function
11. Support backlight adjustment and automatic shutdown
12. IP65 Protection Ratings
13. Standard residual chlorine calibrated Reagent Pack, residual chlorine/total chlorine Reagent Pack and Portable Protective Case
Principle
The instrument irradiates the sample with 515nm LED Illuminant, and automatically calculates the residual chlorine or total chlorine concentration by measuring Absorbance change and intelligently determining the end point of the reaction. Support dilute ratio setting, which can automatically convert the original sample concentration.
Applications
Water quality testing, environment monitoring, drinking water safety, swimming pool water quality control, industrial water treatment
Steps
1. Turn on and select Measurement mode (residual chlorine or total chlorine)
Add Sample and Reagent to 25mm Colorimetric Bottle
3. Colorimetric bottle into the measurement tank
4. The instrument automatically determines the destination and displays the reading
5. If you need to calibrate, execute (1~ 3) point calibrating procedure
6. Data can be stored, transmitted, or printed
Notice
• Operating Environment Temperature 5~ 35 ℃, relative humidity not more than 85%
• Periodically calibrated to ensure Measurement accuracy
• Use Standard Reagent Pack to Avoid Contamination
• Pay attention to the battery status prompt when charging
• Avoid severe impact or water immersion (although with IP65 protection)
• Store data and back it up in time to prevent loss