Overview
The LABTOP UC06 chiller is a high-end model in the uChiller series, designed for high-quality requirements. This model is equipped with a pressure regulating protection bypass valve and a complete protection alarm system. It can be optionally configured to purify water to ensure clean water quality. It provides a variety of alarm and output interfaces, including water pressure protection and water flow alarm protection, and can be configured with different types of circulating pumps according to requirements.
Features
1. Adopting a high-performance circulating water pump, the circulating water system is equipped with multiple water purification designs to prevent impurities from entering and prolong the service life of the pump.
2. Using professional PID control technology, high temperature control accuracy.
3. Use the Pt100 temperature sensor.
4. The system is stable and reliable, using high-performance and high-mass spare parts.
5. Equipped with multiple safety protections, including temperature protection, water pressure protection, overheating and overcurrent protection, and alerted by light and sound when alarming.
6. The refrigeration series adopts imported Compressor and ultra-quiet fan, the whole machine has low working noise and is suitable for laboratory environment.
7. When alarming, the light and sound remind at the same time, and the alarm code is directly displayed, which is convenient for quickly determining the error point.
8. Adopt waterproof keyboard design and LCD display.
9. The maximum and minimum temperature settings of the machine can be limited.
Principle
The chiller drives the chilled down liquid to circulate between the equipment and the external chilled down equipment through the circulation pump. The system uses PID control technology to accurately monitor the temperature through the Pt100 temperature sensor and adjust the cooling capacity of the Compressor to achieve accurate control of the chilled down liquid temperature, ensuring that the temperature is stable within the set range.
Applications
Laboratory and industrial refrigeration
Steps
Connect the power supply (200~ 230VAC/50Hz).
2. Connect the pump interface according to requirements.
3. Temperature range (5~ 35 ℃) through waterproof keyboard and LCD display.
4. Start the equipment, and the system will start to cycle and chill down and precisely control the temperature.
5. During operation, the temperature and equipment status can be monitored through the display screen.
Notice
The equipment allows a continuous operation rate of 100%.
• Ambient Temperature should be in the range of 5~ 32 ℃.
• The relative humidity of the working environment shall not exceed 80%.
• Pay attention to distinguish the model suffix, without "F" for Air-Cooled integrated type, with "F" for cold split.
• In case of an alarm during operation, please check according to the displayed alarm code.