Overview
The LABTOP UC052F is a split chiller consisting of an indoor unit and an outdoor unit. The outdoor unit consists of a refrigeration Compressor, a hot air excretor, and a condenser, which is responsible for discharging heat and main noise generated by refrigeration to the outside; the indoor unit consists of a water pump, a water tank, and an evaporator, which operates quietly and without heat output. This design significantly reduces equipment operating noise, improves operating comfort, and achieves greater refrigeration power output.
Features
1.The split design places the main noise source and heat emission outdoors, and the indoor operation is quiet to improve the comfort of the environment.
2. Equipped with an LCD screen, it can display the actual temperature, set temperature and return difference at the same time, and the information is clear at a glance.
3. Adopting a high-performance circulating water pump, the circulating water system is equipped with multiple water purification designs to effectively prevent impurities from entering and prolong the service life of the pump.
4. Application of professional PID control technology, high temperature control accuracy.
5. The system uses high-performance, high-mass spare parts to ensure stable and reliable operation.
6. Equipped with multiple safety protections, including temperature protection, water pressure protection, overheating and overcurrent protection, and alerted by light and sound when alarming.
7. The refrigeration system adopts imported Compressor and ultra-quiet fan, and the working noise of the whole machine is very low, which is especially suitable for the laboratory environment.
8. The alarm code is displayed directly, which is convenient for quickly determining the fault point.
9. The maximum and minimum temperature settings of the machine can be limited.
Principle
The split chiller achieves cooling through the cooperative work of the indoor unit and the outdoor unit. The refrigeration Compressor in the outdoor unit drives the refrigeration cycle, and the condenser and the exhaust hot air machine discharge the heat generated during the refrigeration process to the outdoor environment. The evaporator in the indoor unit absorbs the heat of the chilled down equipment (or circulating water), and the water pump distributes the chilled down water cycle to the equipment that needs to be chilled down, forming a closed-loop temperature control system.
Applications
X-ray Diffractometer, X Fluorescence Spectrophotometer, Large Emission Electron Microscope, Plasma Etching and other large laboratory equipment, vacuum coating machine, ion coating machine, vacuum furnace, industrial furnace and other industrial equipment with large calorific value
Notice
The equipment allows a continuous operation rate of 100%.
• Ambient Temperature of the equipment should be within the range of 5~ 32 ℃.
• The relative humidity of the equipment operating environment should not exceed 80%.