The LABTOP UC072F is an Air-Cooled split chiller that consists of an indoor unit and an outdoor unit. The outdoor unit contains a refrigeration Compressor, a hot air exhaust unit, and a condenser, which is responsible for discharging the heat and main noise generated by the refrigeration to the outside; the indoor unit contains a water pump, a water tank, and an evaporator, which operates with no heat output and low noise. This design significantly reduces equipment noise levels, improves operating comfort, and provides greater refrigeration power.
Features
1.Split design, the main noise source and heat emissions are placed outdoors, and the indoor operation is quiet and heat-free.
2. Using imported Compressor and ultra-quiet fan, the working noise of the whole machine is very low, suitable for laboratories and other places with high Environmental requirements.
3. Equipped with an LCD screen, it can display the actual temperature, set temperature and return difference at the same time, and the information is clear at a glance.
4. Using professional PID control technology, high temperature control accuracy.
5. The circulating water system adopts a multiple water purification design to prevent impurities from entering and prolong the service life of the pump.
6. Equipped with multiple safety protections, including temperature protection, water pressure protection, overheating and overcurrent protection, lighting and sound simultaneously alert when alarming, and directly display the alarm code to quickly locate the fault.
7. The maximum and minimum temperature limits for machine operation can be set.
8. The system adopts high-performance, high-mass spare parts, and the operation is stable and reliable.
Principle
The chiller adopts a compression refrigeration cycle. The refrigeration Compressor in the outdoor unit compresses the low temperature and low pressure refrigerant gas into a high temperature and high voltage gas, which is cooled and condensed into a high voltage liquid by the exhaust hot air through the condenser. The high voltage liquid refrigerant enters the evaporator of the indoor unit through the pipeline, expands and absorbs heat in the evaporator, so that the circulating water flowing through the evaporator is chilled down. The chilled down water is transported by the high-performance circulating water pump of the indoor unit to the equipment that needs to be chilled down, and the heated water is returned to the evaporator to chill down again, so that the cycle can achieve continuous temperature control.
Applications
X-ray Diffractometer, X Fluorescence Spectrophotometer, Large Emission Electron Microscope, Plasma Etching and other large laboratory equipment, vacuum coating machine, ion coating machine, vacuum furnace, industrial furnace and other industrial equipment with large calorific value
Notice
The equipment allows a continuous operation rate of 100%.
• Ambient Temperature of the equipment should be within the range of 5~ 32 ℃.
• The relative humidity of the equipment operating environment should be ≤ 80%.