Overview
The LABTOP UC145F is a split chiller that consists of an indoor unit and an outdoor unit. The outdoor unit includes a refrigeration Compressor, a hot air drainer, and a condenser, which is responsible for discharging heat and main noise generated by refrigeration to the outside; the indoor unit integrates a water pump, water tank, and evaporator for quiet operation and no heat production. This design significantly reduces equipment noise, improves operating comfort, and enables greater refrigeration power output.
Features
1.Split design, the main noise source and heat emissions are placed outdoors, and the indoor operation is quiet and comfortable.
2. Equipped with an LCD screen, it can simultaneously display the actual temperature, set temperature and return difference, providing intuitive information.
3. Adopting a high-performance circulating water pump, the circulating water system is equipped with multiple purification designs to extend the service life of the pump.
4. Application of professional PID control technology, high temperature control accuracy.
5. Using high-performance, high-mass spare parts, the system is stable and reliable.
6. Equipped with multiple safety protections, including temperature protection, water pressure protection, overheating and overcurrent protection, and alerted by light and sound when alarming.
7. The refrigeration system adopts imported Compressor and ultra-quiet fan, and the working noise of the whole machine is low.
8. The alarm code is displayed directly, which is convenient for quickly locating the fault point.
9. Maximum and minimum temperature limits for the machine can be set.
Principle
The split chiller completes the refrigeration cycle through the refrigeration Compressor, condenser and hot air exhaust of the outdoor unit, and discharges the heat outdoors. The cryogenic refrigerant exchanges heat with the circulating water in the evaporator of the indoor unit to reduce the water temperature. The water pump of the indoor unit transports the chilled down water to the equipment that needs to be chilled down, and the warm water after absorption flows back to the water tank, which is chilled down again by the evaporator to form a cycle to achieve continuous cooling of the equipment.
Applications
X-ray Diffractometer, X Fluorescence Spectrophotometer, Large Emission Electron Microscope, Plasma Etching and other large laboratory equipment, vacuum coating machine, ion coating machine, vacuum furnace, industrial furnace and other industrial equipment with large calorific value.
Notice
The equipment allows a continuous operation rate of 100%.
* The Ambient Temperature of the equipment should be within the range of 5~ 32 ℃.
* The relative humidity of the equipment operating environment should not exceed 80%.