Overview
The LABTOP IC145 chill down circulating water machine is a general-purpose Water-Cooled chill down circulating equipment, which belongs to the IC series. This series of products is widely used, and the minicomputers can be used for laboratory equipment. The IC145 adopts the Water-Cooled cooling method, which has no heat discharge and low noise in the room during operation. It is an environment-friendly product. The equipment has multiple protection functions and provides alarm output for external main equipment. At the same time, it supports multiple Communication interfaces and analog/switch input and output, which can realize remote control and status query.
Features
1. LCD screen, displaying the actual temperature, set temperature and return difference at the same time, the operation is intuitive, and the keyboard is automatically locked when the button operation expires.
2. A variety of pressure pumps are available, and the output pressure of the pump is adjustable, which can meet the various application requirements of different pressures and different Flow rates.
3. Equipped with standby antifreeze function of water pump.
4. Support remote control of the switch machine.
5, using brand Compressor, silent fan and silent pump, quiet when working, suitable for quiet environment applications.
6, refrigeration system with high voltage protection and overcurrent protection function, effectively prevent Compressor overload, protect Compressor.
7. When alarming, the light and sound are reminded at the same time, and the alarm code is directly displayed, making it easy to quickly determine the cause of the failure and the repair method.
8. Adopt caster design to facilitate machine movement.
Principle
The chilled down circulating water machine chills down the circulating water in the liquid storage tank through the built-in refrigeration system (including Compressor, etc.). The chilled down water is output through the circulation pump to provide the external equipment with thermostatic chilled down liquid. The heat is discharged through the Water-Cooled cooling system (instead of the fan), so as to achieve low noise and no heat emission operation indoors. The equipment precisely controls the water temperature through temperature sensors and controllers, and can accept external instructions or external output control signals through the Communication interface.
Applications
General chilled down, laboratory equipment chilled down
Steps
1. Place the device in a stable position with Permissible Ambient Temperature (5~ 32 ° C) and Humidity (≤ 80%), and connect the power supply (200~ 230VAC/50Hz).
2. Connect the chilled down liquid output and return pipeline to the equipment to be chilled down through the device interface (4 points inner teeth).
3. Set the required temperature (range 5 to 35 ° C) and Miscellaneous parameters on the LCD screen.
4. Start the equipment, the circulating pump starts working, and the refrigeration system automatically runs according to the set temperature.
5. Monitor the actual temperature, set temperature, and equipment operating status through the display screen.
6. After use, you can shut down according to the procedures. If you need remote control, you can operate through supported Communication interfaces (such as RS232/RS485/USB).
Notice
* Ambient Temperature (5~ 32 ℃) and relative humidity (≤ 80%).
* Power supply voltage meets requirements (200~ 230VAC/50Hz).
Pay attention to the size of the equipment interface (4-point inner teeth), and use suitable connectors and pipes.
* The equipment is Floor-Standing, please place it on a stable and load-bearing ground.
When an alarm occurs, please follow the alarm code prompt on the display screen for troubleshooting and handling.
When moving the device, use the bottom casters, but be careful to avoid collisions.
* The equipment has the function of standby antifreeze of water pump, please pay attention to the relevant settings in low temperature environment.
* To protect the Compressor, do not switch on and off frequently or overload the equipment.