Temperature range -5~ 100 ℃, Tank volume 20L, Temperature Fluctuation +/- 0.05~ 0.1 ℃. Integrated heating and cooling function, using proportional refrigeration control technology and CIT timely cooling technology, equipped with pressure/suction pump, support internal and external circulation and multiple safety protection.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030817
Service :The delivery and service By NBCLab.Com
The LABTOP CC-0520E high and low temperature thermostatic circulator integrates heating and cooling functions. The water bath body is made of all stainless steel and insulated, providing an economical solution for placing samples directly in the water bath for thermostatic testing. This model has a Tank volume of 20L, Temperature range -5~ 100 ° C, and is equipped with a pressure/suction pump to support domestic circulation and external circulation applications.
Adopting professional proportional refrigeration control technology, the refrigeration capacity is output proportionally, and the Compressor does not need 100% output, which is more energy-saving. 2. With CIT timely cooling technology, the Compressor can be directly started to cool down even at high temperatures. 3. Equipped with low liquid level protection function to prevent dry burning, and can set lighting and sound alarms. 4. Optional multi-stage programmable controller to achieve regular heating, cooling, thermostatic and other program control, the longest time of each period is 999 hours. 5. Equipped with external temperature sensor interface, with PID TAC control, Cascade cascade control and bath inside and outside temperature lock control technology, can accurately control the bath outside the material temperature. 6. Using maintenance-free pressure/suction pump, resistant to fiber and metal particulate matter, the bath liquid can be stirred horizontally and vertically to make the stirring more uniform, and the pump pressure and Flow rate automatically adapt to the external load. 7. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 8. Using the Pt100 temperature sensor, two-point and multi-point temperature calibration is possible. 9. Removable trend dust net cover, easy maintenance. 10. The buzzer can be set to silent or audible. 11. Provide a variety of operation modes, accidental power failure can be automatically restored. 12. Optional intelligent control functions, including a variety of Communication interfaces (RS485, RS232), analog signal input (0-10V or 4-20mA), external touch point and switch signal, realize remote communication and control.
The thermostatic circulator monitors the temperature in real time through the intelligent PID Control system combined with the Pt100 temperature sensor. The system proportionally adjusts the Heating power and cooling capacity according to the deviation of the set value and the actual value (through the proportional refrigeration control technology) to achieve precise temperature control. The circulation pump drives the liquid in the bath for domestic circulation or external circulation, and ensures uniform temperature through horizontal and vertical two-way stirring. When the external Sensor is connected, the external material temperature can be precisely controlled by technologies such as Cascade cascade control.
Sample temperature control, material testing, quality control, analysis
Safety level III/FL can use flammability liquids according to DIN 12876
1. Place the device in a stable and well-ventilated position and connect the power supply (200~ 230VAC/50Hz). 2. Inject an appropriate amount of bath liquid into the bath to ensure that the liquid level is normal and avoid dry burning. 3. Turn on the power switch and set the required temperature value (resolution 0.1 ° C) through the LED display. 4. Select domestic circulation or connect external circulation lines (interface M16x1) as needed. 5. If program control is required, a multi-stage program controller can be selected and installed. 6. If you need external temperature control, you can connect the external temperature sensor PT100. 7. Start the device, the system will start heating or cooling, and automatically adjust to the set temperature. 8. During the operation of the equipment, the real-time temperature and status can be monitored through the display screen. 9. After use, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
• Permissible Ambient Temperature of the equipment is 5~ 32 ℃, relative humidity ≤ 80%, please ensure that it is used in a suitable environment. • Before use, please confirm that the Power supply voltage meets the requirements (200~ 230VAC/50Hz). • Pay attention to the liquid level of the bath to avoid low liquid level dry burning. The equipment has a low liquid level protection function. Equipment is equipped with over-temperature protection, but it is still necessary to avoid long-term overload operation. • When applying external circulation, make sure that the external pipeline connection is firm and there is no leakage. • Regularly clean the removable trend dust net cover to ensure heat dissipation and normal operation. Before moving or maintaining equipment, be sure to disconnect the power supply. • Optional external alarm or control signal interface, please connect and use it correctly as required. Equipment uses environmentally friendly natural refrigerants, and relevant environmental regulations should be followed for maintenance and disposal.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.