Please contact customer service
Temperature range -5~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃. Proportional refrigeration and CIT timely cooling technology, energy saving and efficient. Equipped with pressure/suction pump, support internal and external circulation and multi-stage program control, comprehensive safety protection.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030819
Service :The delivery and service By NBCLab.Com
The LABTOP CC-0527E high and low temperature thermostatic circulator integrates heating and cooling functions. The water bath body is made of all stainless steel, and the external heat insulation provides an economical solution for the thermostatic test of the sample directly placed in the water bath. This model has a Tank volume of 27L and a Temperature range of -5~ 100 ° C. It comes standard with an external circulation adapter and an external temperature sensor PT100. The pump pressure can reach 0.3 bar and the suction force can reach 0.2 bar. suitable for sample temperature control, material testing, quality control, analysis and other fields.
1. Professional proportional refrigeration control technology allows for proportional output of refrigeration capacity, making it more energy-efficient. 2. CIT timely cooling technology, high temperature can directly start Compressor cooling. 3. Low liquid level protection to prevent dry burning, alarm and light sound reminder. 4. Optional multi-stage programmable controller to achieve multi-stage program control (such as timing heating, cooling, thermostatic). 5. Equipped with external temperature sensor interface, with PID TAC control, Cascade cascade control and other technologies, can accurately control the external material temperature of the bath. 6. Can be domestic circulation, external circulation, equipped with maintenance-free pressure/suction pump, resistant to fiber and metal particles, can be horizontal and vertical two-way mixing of bath liquid, pump pressure and Flow rate automatically adapt to external load. 7. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 8. Pt100 temperature sensor, can perform two-point and multi-point temperature calibrating. 9. Removable into the trend dust net cover, easy maintenance. 10. The buzzer can be set to silent or audible. 11. Multiple operation modes are optional (automatic recovery after power failure), and accidental power failure can be automatically restored. 12. Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication; optional analog signal input (0-10V or 4-20mA) for external device control; optional external contact point connection alarm; optional switch Output signal control external solenoid valve; optional external input switch signal control instrument start and stop. 13. The device serial number can be queried through the software.
The device precisely adjusts the temperature of the medium in the water bath through an integrated heating and cooling system combined with intelligent PID temperature control technology. With proportional refrigeration control technology, the Compressor does not need to output 100%, and provides cooling capacity on demand. Equipped with a pressure/suction pump, the liquid in the tank can be circulated and stirred, and the external temperature sensor PT100 and cascade control technology can achieve precise temperature control of the external materials of the bath.
Sample temperature control, material testing, quality control, analysis
Safety level III/FL can use flammability liquids according to DIN 12876
1. Ensure that the power supply of the equipment meets the requirements (200~ 230VAC/50Hz), the Ambient Temperature is 5~ 32 ℃, and the relative humidity is ≤ 80%. 2. Add the appropriate medium to the appropriate liquid level in the Tank to ensure that the liquid level protection function is normal. 3. Connect the power supply and turn on the power switch of the device. 4. Set the required temperature parameters through the LED display. For multi-stage program control, use the optional multi-stage programmable controller to set. 5. For external temperature control or circulation, connect the standard external circulation adapter and the external temperature sensor PT100. 6. Select the domestic circulation or external circulation mode as needed, and start the pressure/suction pump. 7. When the equipment starts working, the intelligent PID Control system will automatically adjust the heating and cooling to maintain the set temperature. 8. After use, turn off the power supply of the equipment and do a good job of cleaning and maintenance.
• Please ensure that the equipment is used under allowable environmental conditions (temperature 5~ 32 ℃, Humidity ≤ 80%). • Please check the liquid level before use to avoid dry burning, and pay attention to the low liquid level protection alarm prompt. Equipment is equipped with over-temperature protection, but it is still necessary to avoid long-term overload operation. • Before performing maintenance (such as cleaning the dust net cover), be sure to disconnect the power supply of the equipment. • If flammability liquids are required, ensure compliance with Safety level III/FL. When connecting external devices or performing remote control, please refer to the optional function description for proper wiring. • The maximum pressure of the pump is 0.3 bar, and the maximum suction force is 0.2 bar. Please do not use it beyond the limit. The equipment is allowed to operate continuously for 100%, but it is still recommended to check the operating status regularly.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.