Temperature range -25~ 200 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, integrated heating and cooling function, equipped with pressure/suction pump, support internal and external circulation and external temperature control, with multiple Safety protection.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030822
Service :The delivery and service By NBCLab.Com
The LABTOP CC-2508 high and low temperature thermostatic circulator integrates heating and cooling functions. The water bath body is made of all stainless steel and insulated, providing an economical solution for the thermostatic test of the sample directly placed in the water bath. This model has a Tank volume of 8L and a Temperature range of -25~ 200 ° C. It comes standard with an external circulation adapter and an external temperature sensor PT100. The pump pressure can reach 0.7bar. The suction force can reach 0.4bar. It is suitable for the fields of temperature control, material testing, quality control and chemical analysis of samples.
Professional proportional refrigeration control technology, refrigeration output in proportion, Compressor without 100% output, more energy saving. 2. CIT timely cooling technology, even at high temperatures can directly start the Compressor cooling. 3. Low liquid level protection to prevent dry burning, alarm and accompanied by lighting and sound reminders. 4. Optional multi-segment programmable controller, users can realize multi-segment program control, such as timing heating, cooling, thermostatic and setting each period of time. 5. Equipped with external temperature sensor interface, optional movable external temperature sensor, with PID TAC control, Cascade cascade control and bath internal and external temperature lock control technology, can accurately control the bath external material temperature. 6. Can be domestic circulation, external circulation, maintenance-free pressure/suction pump, resistant to fiber and metal particles, can be stirred in the horizontal and vertical directions of the bath liquid, so that the mixing is more uniform, pump pressure and Flow rate automatically adapt to external load. 7. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 8. Pt100 temperature sensor, can perform two-point and multi-point temperature calibrating. 9. Removable trend dust net cover, easy maintenance. 10. The buzzer can be set to silent or audible. 11. Multiple operation modes are optional, and accidental power failure can be automatically restored. 12. Optional intelligent control functions: a variety of interfaces (RS485, RS232) to achieve remote communication and control the start and stop of equipment. 13. Optional 0-10V or 4-20mA analog signal input can be used for external smart devices to control the start and stop of the instrument. 14. The device serial number can be queried through the software. 15. Optional normally open and normally closed 2 external contact points, can be connected to external alarms. 16. Optional set of 12V switch Output signal for controlling external solenoid valve. 17. An optional set of 5V external input switch signals can be used for external smart devices to control the start and stop of the instrument.
The thermostatic circulator precisely senses the temperature of the bath or external materials through an intelligent PID Control system combined with a Pt100 temperature sensor. Temperature regulation with an integrated heating and cooling module (using environmentally friendly natural refrigerants). The domestic circulation of the bath liquid is driven by a maintenance-free pressure/suction pump, and the bath liquid can be stirred horizontally and vertically to ensure uniform temperature. When connected to an external Sensor, the system can use technologies such as Cascade cascade control to achieve precise temperature control of the external materials of the bath.
Sample temperature control, material testing, quality control, chemical analysis
Safety level III/FL can use flammability liquids according to DIN 12876
1. Ensure that the equipment is placed in the allowable environment conditions (Ambient Temperature 5~ 32 ℃, relative humidity ≤ 80%), and connect to the required power supply (200~ 230VAC/50Hz). 2. Add an appropriate amount of bath liquid to the Tank, pay attention to the liquid level, and avoid dry burning. 3. Optionally connect external temperature sensor PT100 or external circulation adapter. 4. Set the required temperature program (including heating, cooling, thermostatic and various periods) through the instrument panel or optional multi-stage programming controller. 5. Select the operation mode (such as power failure recovery mode) and buzzer prompt mode as needed. 6. Start the equipment and the system will start working, ensuring uniform temperature through pump circulation and stirring. 7. During operation, the real-time temperature (resolution 0.01 ° C) and equipment status can be monitored through the LED display. 8. After the experiment, shut down the equipment according to the procedures and perform necessary cleaning and maintenance (e.g. cleaning the removable dust net cover).
Please read the instructions carefully before use and ensure that the operator is trained. * Equipment must operate at the allowable Ambient Temperature (5~ 32 ° C) and relative humidity (≤ 80%). * Power supply voltage 200~ 230VAC/50Hz, and reliable grounding. Be sure to check the liquid level of the bath before operation to prevent low-level dry burning. The equipment has a low-level protection function. The equipment is equipped with over-temperature protection, but it is still necessary to avoid long-term overrun. * When using flammability liquids as bath liquids, ensure compliance with Safety level III/FL requirements. The maximum pressure and suction of the pump should not exceed the rated value (pressure 0.2 bar, suction 0.1 bar, specific models may be higher). When performing external loops or connecting external devices, ensure that the interface (e.g. M16x1) is firmly connected and leak-free. * Regularly clean the removable trend dust net cover to ensure heat dissipation and normal operation. Before moving or maintaining equipment, be sure to disconnect the power supply. * If the device alarms (e.g. low liquid level, over temperature), please check the cause in time, and do not force operation before Troubleshooting. * For the installation and use of optional functions (such as remote communication, external alarm touch points, etc.), please refer to the relevant option instructions.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.