Temperature range of -25~ 250 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃. Proportional refrigeration and CIT timely cooling technology, energy saving and efficient; equipped with maintenance-free pressure/suction pump, support internal and external circulation and uniform mixing.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030823
Service :The delivery and service By NBCLab.Com
The LABTOP CC-2508P high and low temperature thermostatic circulator integrates heating and cooling functions. The water bath body is made of all stainless steel and insulated, providing an economical solution for the thermostatic test of the sample directly placed in the water bath. This model has a Tank volume of 8L and a Temperature range of -25~ 250 ° C. It comes standard with an external circulation adapter and an external temperature sensor PT100. The pump is powerful, with a pressure of up to 0.7 bar and a suction force of up to 0.4bar. Suitable for temperature control, material testing, quality control, analysis of samples, etc.
Professional proportional refrigeration control technology, refrigeration output in proportion, Compressor without 100% output, more energy saving. 2. CIT timely cooling technology, even at high temperatures can directly start the Compressor cooling. 3. Low liquid level protection to prevent dry burning, can alarm and remind with light and sound at the same time. 4. Optional multi-stage programmable controller, users can achieve multi-stage program control, such as regular heating, cooling, thermostatic, slope and each period of time, the longest time 999 hours. 5. Equipped with external temperature sensor interface, optional movable external temperature sensor, with PID TAC control, Cascade cascade control and bath internal and external temperature lock control technology, precise control of bath external material temperature. 6. Can be domestic circulation, external circulation, equipped with maintenance-free pressure/suction pump, resistant to fiber and metal particles, can be horizontal and vertical two-way mixing of bath liquid, so that the mixing is more uniform, pump pressure and Flow rate automatically adapt to external load. 7. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 8. Pt100 temperature sensor, can perform two-point and multi-point temperature calibrating. 9. Removable trend dust net cover, easy maintenance. 10. The buzzer can be set to silent or audible. 11. Multiple operation modes are optional, and accidental power failure can be automatically restored. 12. Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication, control equipment start and stop. 13. Optional 0-10V or 4-20mA analog signal input for external smart devices to control the start and stop of the instrument. 14. The device serial number can be queried through the software. 15. Optional normally open and normally closed 2 external contact points, can be connected to external alarms. 16. Optional set of 12V switch Output signal for controlling external solenoid valve. 17. An optional set of 5V external input switch signals can be used for external smart devices to control the start and stop of the instrument.
The thermostatic circulator accurately detects the temperature through the intelligent PID Control system combined with the Pt100 temperature sensor. System integration heating and cooling function, using proportional refrigeration control technology to output the cooling capacity on demand, and through the CIT technology implementation of high temperature rapid start Compressor cooling. Circulation pump drives the bath liquid in the tank or external circulation, and horizontal and vertical two-way stirring to ensure uniform temperature. Multiple control technologies (such as PID TAC, Cascade cascade control, temperature difference lock control) cooperate with the external Sensor to achieve accurate temperature control of the external material of the bath.
Sample temperature control, material testing, quality control, analysis
Safety level III/FL can use flammability liquids according to DIN 12876
1. Check the Power supply voltage (200~ 230VAC/50Hz) and environmental conditions (Temperature 5~ 32 ℃, Humidity ≤ 80%). 2. Add an appropriate amount of bath liquid to the bath to ensure that the liquid level is normal and avoid dry burning. 3. Connect the power supply and turn on the power switch of the device. 4. Set the required temperature, program (up to 30 segments) and Miscellaneous parameters (such as running time, slope) through the LED display and controller. 5. Connect external circulation pipeline or external temperature sensor (PT100) as needed. 6. Start the equipment, the circulating pump starts to work, and the equipment is heated, cooled or thermostatic controlled according to the settings. 7. During operation, real-time temperature, program segment status, and other information can be monitored through the display screen. 8. When the operation is over or needs to be stopped, press the stop button to stop the heating/cooling and circulation of the equipment. 9. Turn off the power supply, if you need cleaning or maintenance, you can remove it into the trend dust net cover for cleaning.
• Before use, please ensure that the Power supply voltage of the equipment meets the requirements (200~ 230VAC/50Hz). Equipment should operate under permissible environment conditions (Ambient Temperature 5~ 32 ℃, relative humidity ≤ 80%). • Pay attention to the liquid level of the bath to avoid low liquid level dry burning. The equipment has a low liquid level protection function. Equipment is equipped with over-temperature protection, but it is still necessary to avoid long-term overload operation. • When using flammability liquids, ensure compliance with Safety level III/FL standards. • When external cycling or using an external Sensor, make sure the connection is correct and the sealing is good. • Regularly clean the removable trend dust net cover to keep the equipment well dissipated. • The device has a variety of power-off recovery modes, please set it before operation according to actual needs. • When performing program control, please carefully set the parameters of each section (temperature, time, slope, etc.). When maintaining, ensure that the equipment is powered off and that components that come into contact with liquids or steam are made of stainless steel or high-performance plastics.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.