Please contact customer service
Temperature range -30~ 220 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃. Proportional refrigeration and CIT timely cooling technology are adopted, energy saving and efficient; support internal and external circulation and multi-stage program control, with multiple safety protection.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030825
Service :The delivery and service By NBCLab.Com
The LABTOP CC-3013 high and low temperature thermostatic circulator integrates heating and cooling functions. The water bath body is made of all stainless steel, and the external heat insulation provides an economical solution for the thermostatic test of the sample directly placed in the water bath. This model has a Tank volume of 13L and a Temperature range of -30~ 220 ° C. It comes standard with an external circulation adapter and an external temperature sensor PT100. The pump function is more powerful, the pressure can reach 0.7bar, and the suction force can reach 0.4bar. It is suitable for temperature control of samples, material testing, quality control and chemical analysis.
Professional proportional refrigeration control technology, refrigeration output in proportion, Compressor without 100% output, more energy saving. 2. CIT timely cooling technology, even at high temperatures can directly start the Compressor cooling. 3. Low liquid level protection to prevent dry burning. 4. Optional multi-segment programmable controller, users can realize multi-segment program control, such as timing heating, cooling, thermostatic and setting each period of time. 5. Equipped with external temperature sensor interface, with PID TAC control, Cascade cascade control and bath inside and outside temperature lock control technology, can accurately control the bath outside the material temperature. 6. Can be domestic circulation, external circulation, equipped with maintenance-free pressure/suction pump, resistant to fiber and metal particles, can be horizontal and vertical two-way mixing of bath liquid, so that the mixing is more uniform, pump pressure and Flow rate automatically adapt to external load. 7. Multiple safety protection: low liquid level protection, alarm can be alerted by light and sound at the same time. 8. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 9. Pt100 temperature sensor, two-point and multi-point temperature calibrating. 10. Removable trend dust net cover, easy maintenance. 11. The buzzer can be set to silent or audible. 12. Multiple operation modes are optional, and accidental power failure can be automatically restored. 13. Optional intelligent control functions: a variety of interfaces (RS485, RS232), to achieve remote communication, control equipment start and stop. 14. Optional 0-10V or 4-20mA analog signal input for external smart devices to control the start and stop of the instrument. 15. The device serial number can be queried through the software. 16. Optional normally open and normally closed 2 external contact points, can be connected to external alarms. 17. Optional set of 12V Switch Output signal for controlling external solenoid valve. 18. An optional set of 5V external input switch signals can be used for external smart devices to control the start and stop of the instrument.
The thermostatic circulator uses the Pt100 temperature sensor to accurately sense temperature changes through intelligent PID Control mode. System integration of heating and cooling functions, using proportional cooling control technology, according to the difference between the set temperature and the current temperature, according to the proportional output cooling capacity, instead of Compressor full Power operation, to achieve high-efficiency and energy-saving temperature regulation. At the same time, through the pressure/suction pump to drive the bath liquid for domestic circulation or external circulation, and combined with horizontal and vertical two-way stirring to ensure uniform temperature in the bath. When external temperature control, external temperature sensors can be connected, and the use of Cascade cascade control technology, to achieve precise control of the temperature of the external material bath.
Sample temperature control, material testing, quality control, chemical analysis
Safety level III/FL can use flammability liquids, DIN 12876
1. Check the Power supply voltage (200~ 230VAC/50Hz) and environmental conditions (Permissible Ambient Temperature 5~ 32 ℃, relative humidity 80%). 2. Add an appropriate amount of bath liquid to the Tank, pay attention to the liquid level, and avoid dry burning. 3. Connect the power supply and turn on the power switch of the device. 4. Set the required temperature and control parameters through the LED display and controller (if necessary, multi-stage programming can be performed). 5. If external circulation temperature control is required, connect the external circulation pipeline and the external temperature sensor PT100. 6. Start the equipment, start the heating or cooling system, and start the pump at the same time for circulating stirring. 7. During the operation of the equipment, the real-time temperature and status can be monitored through the display screen. 8. After the experiment, power off the device and disconnect the external connection (if any). 9. Clean equipment, especially removable trend dust net cover.
• Power supply voltage meets requirements (200~ 230VAC/50Hz) before use. • Equipment should operate at the allowable Ambient Temperature (5~ 32 ° C) and relative humidity (≤ 80%). • Pay attention to the Tank level to prevent low-level dry burning. The equipment has a low-level protection function. The equipment has an over-temperature protection function, but it is still necessary to avoid long-term over-temperature operation. • The pump connection interface is M16x1, please ensure good sealing when connecting the external circulation pipeline. • The equipment is Floor-Standing fixed, please place it in a stable and well-ventilated position. • Allows 100% continuous operation, but regular inspections and maintenance are recommended. When cleaning or maintaining, disconnect the power supply. • Optional functions (such as multi-stage programming, external interfaces, alarm touch points, etc.) need to be operated according to the actual configuration. • The buzzer alarm volume can be set to audible or silent mode as required.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.