Please contact customer service
Temperature range -20~ 100 ℃, with 30 program control function, support Touchscreen operation and proportional cooling combined with PID CIT technology, can directly high temperature cooling, pump pressure automatically adapt to external load.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030831
Service :The delivery and service By NBCLab.Com
The LABTOP iCoolero-2006 + external circulation high and low temperature thermostatic circulator provides an economical and environmentally friendly high and low temperature thermostatic circulation solution for laboratories. Its compact structure, small size, and quiet work can be used directly in the desktop or fume cupboard. The device provides three external circulation Temperature control modes of internal control, sample control, and tracking setting control, which can control the temperature of the sink, the temperature of the external material, and slope control respectively. The program-controlled type supports 30-stage program setting, which is convenient for multi-stage control of heating, thermostatic, and cooling. It is especially suitable for temperature control of Glass/Metal Reaction Kettle jackets and internal materials, as well as Miscellaneous applications that require external thermostatic control.
1. Touchscreen TFT display, touch operation, compact size. 2. Combining proportional refrigeration with PID control technology, CIT technology supports direct cooling at high temperatures. 3. Equipped with maintenance-free pressure/suction pump, resistant to fiber and metal particles, long life, pump pressure and Flow rate automatically adapt to external loads, effectively protect external equipment (especially Glass parts). 4. Programmable control (optional), support editing 30 programs to achieve liquid temperature heating, cooling, thermostatic and other combinations of control. 5. The sealing water tank has an intuitive liquid level window, which is convenient for observing the liquid level and has a protective overflow port. 6. Using high-performance and high-mass spare parts, the system is stable and reliable. 7. Equipped with multiple safety protections: water shortage protection, temperature protection, water pressure protection, overheating and overcurrent protection, and lighting and sound reminders when alarming. 8. When alarming, the light and sound remind at the same time, the buzzer can be set to sound or silent, and the alarm code is directly displayed, which is convenient for quickly locating errors. 9. Equipped with internal and external Pt100 temperature sensors, support single-point and two-point temperature calibrating, and can control the temperature of external materials. 10. Multiple operation modes are optional, and accidental power failure can be automatically restored to ensure the continuous supply of chilled down circulating water. 11. Optional intelligent control function: Provide a variety of interfaces (RS485, RS232), allowing remote start-stop control through 0-10V or 4-20mA analog signal input. 12. Use environmentally friendly refrigerants without toxic contamination. 13. The maximum and minimum temperature settings of the machine can be limited.
The device uses a pressure/suction pump to circulate the thermostatic medium (chill down liquid) to an external device (such as Reaction Kettle jacket or internal) through an external circulation temperature control system to achieve accurate temperature control of the target material. Combining proportional refrigeration, PID control and CIT technology, it can quickly Response and stabilize at the set temperature. The device supports multiple temperature control modes (internal control, sample control, tracking setting control) and programmed temperature Linear dispersion management. Real-time temperature monitoring and feedback adjustment through built-in and external Pt100 Sensors ensure Temperature Fluctuation as low as 0.05K.
Glass Reaction Kettle Jacket Temperature Control, Metal Reaction Kettle Jacket Temperature Control, Reaction Kettle Internal Material Temperature Control, Miscellaneous Applications requiring External Therstatic Control
DIN 12876
1. Check the liquid level of the equipment to ensure it is within a safe range. 2. Connect the external circulation line to the target device (e.g. Reaction Kettle). 3. Turn on the power supply and start the device. 4. Select the temperature control mode (internal control, sample control, or tracking setting control) through the Touchscreen. 5. Set the target temperature and program (if necessary, up to 30 heating, thermostatic, and cooling programs can be set). 6. Start the circulation pump and start the thermostatic cycle. 7. During operation, real-time temperature and equipment status can be monitored through the screen. 8. After use, stop the device according to the program and disconnect the power supply from the external connection.
• Please ensure that the device operates at the allowable Ambient Temperature (5~ 32 ° C) and relative humidity (≤ 80%). • Be sure to check the water tank level before use to avoid running short of water. When connecting the external pipeline, please pay attention to the interface specification (ID = 8) to ensure good sealing. • Pay attention to the maximum pressure (0.3 bar) and maximum suction (0.2 bar) limits of the pump to avoid overloading. • When the equipment alarms, please check the fault in time according to the displayed alarm code. • Regularly calibrate the temperature to ensure temperature control accuracy. Before moving or maintaining equipment, be sure to disconnect the power supply. • Do not block the ventilating port when the device is running, so as not to affect the heat dissipation. • Only for professionals who understand the Operation Manual.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.