Please contact customer service
With proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30-stage program control. Adopt maintenance-free pressure pump, maximum Flow rate 22L/min, integrated multiple Safety protection system.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030833
Service :The delivery and service By NBCLab.Com
The external circulation high and low temperature thermostatic circulator iCooler- 2009 + provides an economical and environmentally friendly high and low temperature thermostatic circulation solution for the laboratory. The compact structure design makes it small in shape and quiet in work, and can be used directly on the desktop and ventilated window. The external circulation Temperature control mode can be used in three ways: internal control, sample control, and tracking setting control, which control the temperature of the sink, the temperature of the external material and slope control respectively. The program control type can perform 30-stage program control, which is convenient for multi-stage control such as heating, thermostatic, and cooling.
1. Touchscreen TFT display, touch operation, compact size 2. Combining proportional refrigeration and PID control technology, CIT technology can directly cool down even at high temperatures 3. Maintenance-free pressure/suction pump, resistant to fiber and metal particles, long life, pump pressure and Flow rate automatically adapt to external loads, effectively protect external equipment, especially Glass parts 4. Programmable control, can edit 30 programs to achieve liquid temperature heating, cooling, thermostatic and other combination control (optional) 5. The sealing water tank has an intuitive liquid level window, which is convenient for observing the liquid level and setting a protective overflow port to prevent accidents 6. Stable and reliable system: high-performance high-mass spare parts, stable mass, reliable performance 7. Multiple safety protection: water shortage protection, temperature protection, water pressure protection, overheating and overcurrent protection, light and sound reminder at the same time when alarming 8. When alarming, the light and sound remind at the same time, the buzzer can be set silent or sound, various alarm codes can be directly displayed, and the error point can be directly determined 9. Internal and external PT100 temperature sensor, single point and two point temperature calibrated, external material temperature control 10. Multiple operation modes are available, accidental power failure can be automatically restored to ensure continuous supply of chilled down circulating water 11. Optional intelligent control function: multiple interfaces (RS485, RS232), remote control of machine start/stop can be achieved through 0-10V or 4-20mA analog signal input 12. Environmentally friendly refrigerant, non-toxic pollution 13. The maximum and minimum temperature settings of the machine can be limited
The external circulation thermostatic circulator uses a combination of proportional refrigeration and PID control technology to monitor temperature through internal and external Pt100 temperature sensors for precise temperature control. The system circulates the chilled down liquid through a pressure/suction pump, and the pump pressure and Flow rate automatically adapt to the external load to ensure a continuous supply of thermostatic liquid. CIT technology enables direct cooling of the equipment even in high temperature environments.
Glass Reaction Kettle, Metal Reaction Kettle Jacket Temperature Control, Reaction Kettle Internal Material Temperature Control, any external application requiring thermostatic control
DIN 12876
1. Connect the power supply and equipment 2. Parameter setting through Touchscreen TFT 3. Select Temperature Control mode (Internal Control, Sample Control or Tracking Settings Control) 4. Temperature range and operating parameters 5. Start the device running 6. Monitor operating status and alarm information
• Equipment Permissible Ambient Temperature 5~ 32 ℃ • Allowable relative humidity not exceeding 80% • Pay attention to the liquid level window of the water tank to ensure that the liquid level is normal • Deal with the fault code in time when alarming • Regularly check the operating status of the equipment • Power supply voltage in 200~ 230VAC/50Hz range
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.