Please contact customer service
Temperature range -20~ 100 ℃, Touchscreen operation can edit 30 programs. With proportional cooling and PID control technology, the pressure/suction pump can automatically adapt to external loads and protect external equipment.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030837
Service :The delivery and service By NBCLab.Com
The LABTOP iCoolero-2006P external circulation high and low temperature thermostatic circulator provides an economical and environmentally friendly high and low temperature thermostatic circulation solution for laboratories. Its compact structure, small size, and quiet operation can be used on a desktop or in an fume cupboard. The device provides three temperature Control modes of internal control, sample control, and tracking setting, which can control the temperature of the sink, the temperature of the external material and the slope. The program control type also supports 30 program settings, which is convenient for multi-stage control of heating, thermostatic, and cooling. It is especially suitable for temperature control of Glass Reaction Kettle, Metal Reaction Kettle jacket and internal materials, as well as Miscellaneous applications that require external thermostatic control.
1. Touchscreen TFT display, touch operation, compact size. 2. Combining proportional refrigeration and PID control technology, CIT technology can directly cool down even at high temperatures. 3. Maintenance-free pressure/suction pump, resistant to fiber and metal particles, long life, pump pressure and Flow rate automatically adapt to external loads, effectively protect external equipment, especially Glass parts. 4. Programmable control, can edit 30 programs to achieve liquid temperature heating, cooling, thermostatic and other combined controls (optional). 5. The sealing water tank has an intuitive liquid level window, which is convenient for observing the liquid level. At the same time, the water tank is set to protect the overflow port to prevent accidents. 6. Stable and reliable system: high-performance high-mass spare parts, stable mass, reliable performance. 7. Multiple safety protection: water shortage protection, temperature protection, water pressure protection, overheating and overcurrent protection, and can be reminded by light and sound at the same time when alarming. 8. When alarming, the light and sound remind at the same time, the buzzer can be set silent or sound, and various alarm codes can be directly displayed to directly determine the error point. 9. Internal and external PT100 temperature sensor, single point and two point temperature calibrated, can control the temperature of external materials. 10. A variety of operation modes are available, and unexpected power outages can be automatically restored to ensure the continuous supply of chilled down circulating water. 11. Optional intelligent control functions: a variety of interfaces (RS485, RS232), allowing remote control of machine start/stop through 0-10V or 4-20mA analog signal input. 12. Environmentally friendly refrigerant, non-toxic pollution. 13. The maximum and minimum temperature settings of the machine can be limited.
The device uses external circulation Temperature control mode, through the built-in pressure/suction pump to circulate the thermostatic liquid to an external device (such as Reaction Kettle jacket or internal), to achieve precise temperature control of the target material. It combines proportional cooling with intelligent PID control technology, and uses CIT technology implementation of direct cooling at high temperature. The device monitors the temperature in real time through internal and external Pt100 temperature sensors, and makes precise temperature adjustment according to the set control mode (internal control, sample control or tracking setting control) or program section (such as 30-segment program control).
Glass Reaction Kettle, Metal Reaction Kettle Jacket Temperature Control, Reaction Kettle Internal Material Temperature Control, any external application requiring thermostatic control
DIN 12876
Connect the power supply (200~ 230VAC/50Hz). 2. Check through the liquid level window and ensure that the chilled down liquid in the Tank (volume 6L) is sufficient. 3. Use the ID = 8 interface to connect the external device circulation line. 4. Select Temperature Control mode (Internal Control, Sample Control or Tracking Settings Control) on the Touchscreen TFT display. 5. Set the target temperature (Temperature range -20~ 100 ℃) and program (if necessary, 30 program settings can be performed). 6. Start the equipment and the pressure/suction pump starts to work (maximum Flow rate 22L/min). The equipment will automatically heat (Heating power 1500W), cool (700W at 10 ° C) and cycle according to the settings to achieve and maintain the target temperature. 8. Temperature (resolution 0.01 ° C) and equipment status can be monitored through the display screen during operation. 9. After use, stop the device according to the program and disconnect the power supply.
* Please ensure that the device operates at the allowable Ambient Temperature (5~ 32 ° C) and relative humidity (≤ 80%). * The noise of the equipment is less than or equal to 55dB, please place it in a stable and well ventilated position. * Pay attention to observe the liquid level window of the water tank to ensure that the chilled down liquid is sufficient to avoid water shortage operation. The equipment is equipped with multiple safety protections (water shortage, temperature, water pressure, overheating and overcurrent protection). When alarming, please check the problem in time according to the displayed alarm code. The buzzer alarm tone can be set to audible or silent as required. When connecting external equipment, pay attention to the maximum pressure (0.3 bar) and maximum suction force (0.2 bar) of the pump to avoid overload damage, especially for Glass parts. * Use environmentally friendly refrigerant R404a, but it still needs to be operated and maintained according to specifications. Equipment is allowed to operate continuously for 100%, but long-term operation requires regular inspections. * For temperature calibrating, single point or two point Adjustment can be used. * Optional RS232, USB and other interfaces for remote control, please follow the instructions to connect correctly. * Power supply voltage needs to match 200~ 230VAC/50Hz. The maximum and minimum temperature of the machine can be limited, please set it reasonably according to actual needs.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.