Overview
The LABTOP CC-0513 Pro calibrated Thermostatic bath is a vertical design thermostatic device with a Temperature range of -5 to 100 ° C, suitable for calibrating and test scenarios with high temperature accuracy requirements. The device uses jet flow technology implementation of internal circulation to ensure Temperature uniformity; equipped with High Accuracy 4-wire Pt100 temperature sensor, high temperature Stability, and intuitive operation and status display through LCD touch screen.
Features
1. Compact size, vertical design, suitable for desktop calibrating test.
2. Maintenance-free pressure/suction pump, which can carry out horizontal and vertical two-way stirring of the bath liquid to improve Temperature uniformity.
3. Equipped with low liquid level protection function, it can be alerted by light and sound at the same time when alarming.
4. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and plastics.
5. Adopt Pt100 temperature sensor, support single point and two point temperature calibrating.
6. It can be circulated inside and outside, and the black body with left and right handles is standard, which is convenient for pick and place and installation.
7. The buzzer can be set to either sound or silent mode.
8. The device serial number can be queried through the software.
9. Provide a variety of operation modes, which can be automatically restored after unexpected power failure.
10. Optional 0-10V or 4-20mA analog signal input for external smart devices to control the start and stop of the instrument.
Principle
Calibrate Thermostatic bath works through the built-in heating system and circulating pump (Flow rate 12L/min) to heat and force circulation of the medium in the tank. Jet flow technology is used to stir the bath liquid to ensure uniform temperature in the working area. High Accuracy Pt100 Sensor monitors the temperature in real time, and the Control system precisely adjusts according to the difference between the set value and the actual value to maintain a stable temperature environment.
Applications
Government Measurement Department, Social Measurement Agency, ** equipment inspection department, electronic component testing, aerospace, experiments and factories that require high temperature accuracy
Standards
The data did not mention specific compliance criteria.
Steps
The information does not provide specific operation steps.
Notice
• Ambient Temperature should be between 5 and 32 ℃.
• The relative humidity of the working environment should be ≤ 80%.
• Power supply voltage needs to be 200~ 230VAC/50Hz.
• Pay attention to the low liquid level alarm prompt of the equipment and deal with it in time.