Please contact customer service
Adopt pressure suction pump to automatically adapt to external load, maximum Flow rate 12L/min; support multi-stage program control, each section is up to 999 hours; with hardware over-temperature protection and liquid level protection functions, in line with safety standards.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030853
Service :The delivery and service By NBCLab.Com
The BC206E bath thermostatic circulator is a thermostatic circulator with heating head from the BC series of the LABTOP brand. It uses a chill down coil and an external circulating water or chill down tank. The temperature can reach room temperature or -20 ° C. The bath body is made of all stainless steel and filled with aluminum silicate cotton insulation, providing an economical solution for the thermostatic test of the sample directly placed in the water bath. Optional external circulation adapter and external temperature sensor PT100 are available for external temperature control and circulation applications. It is suitable for sample temperature control, material testing, quality control and analysis. It uses environmentally friendly natural refrigeration with liquid level protection and over-temperature protection.
1. Hardware over-temperature protection, users can set the protection temperature through the knob to avoid dry burning when the equipment program fails, in line with DIN12876 standard level III, flammability bath liquid can be used. 2. Maintenance-free pressure/suction pump, pump pressure and Flow rate automatically adapt to external load. 3. Optional multi-stage programmable controller, support multi-stage program control, such as regular heating, cooling, thermostatic, slope and each period of time, each program can set the running time, up to 999 hours. 4. Equipped with external temperature sensor interface, optional movable external temperature sensor, with PID TAC control technology, Cascade cascade control technology and bath internal and external temperature lock control technology, precise control of bath external material temperature. 5. Pt100 temperature sensor, supports single point, two point and multi point temperature calibrating. 6. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 7. Optional related accessories can be used to form different internal and external applications. 8. The buzzer can be set to silent or audible. 9. Multiple operation modes are optional, and accidental power failure can be automatically restored: Mode 1 (power-on equipment stops after power failure, setting value can be changed), Mode 2 (power-on automatic operation after power failure, setting value can be changed), Mode 3 (power-on automatic operation after power failure, setting value cannot be changed). 10. The device serial number can be queried through the software. 11. Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication, control equipment start and stop. 12. Optional normally open and normally closed 2 external contact points, connected to the external alarm. 13. Optional set of 12V switch Output signal to control external solenoid valve. 14. Optional set of 5V external input switch signals for external smart devices to control the start and stop of the instrument. 15. Optional 0-10V or 4-20mA analog signal input for external smart devices to control the start and stop of the instrument.
The BC206E bath thermostatic circulator achieves temperature control via a heating head and chill down coil, and adjusts the temperature to room temperature or -20 ° C with the help of external circulating water or chill down bath. Intelligent PID control technology and Pt100 temperature sensor for precise temperature monitoring and regulation, combined with pressure/suction pump to automatically adapt to external loads to ensure a thermostatic environment. Optional external Sensor and Adapter for extended external temperature control applications.
Sample temperature control, material testing, quality control, analysis
DIN 12876
1. Connect the power supply to ensure that the Ambient Temperature is 5~ 32 ° C and the relative humidity does not exceed 80%. 2. Set temperature and protection parameters as required, optional external Sensor or accessories. 3. Start the device and monitor the temperature through the LED display with a resolution of 0.1 ° C. 4. Optional programming mode to set up multi-stage programs, such as heating, cooling or thermostatic. 5. Use the pump for circulation, the maximum pressure is 0.2bar, the suction force is 0.1bar, and the Flow rate is 12L/min. 6. Equipment can be remotely controlled or handled during operation to recover from unexpected power outages.
• Power supply voltage 200~ 230VAC/50Hz to avoid over-range use. The equipment is allowed to operate continuously for 100%, but it needs to be operated within the Permissible Ambient Temperature 5~ 32 ° C and 80% relative humidity. • When using flammability bath, confirm that it meets the Safety level III standard. • Regularly check the liquid level protection and over-temperature protection functions to prevent dry burning. • Optional accessories installation, follow the instructions to avoid damage. • In power-off recovery mode, select the appropriate operation mode (mode 1, 2 or 3) according to your needs.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.