Please contact customer service
Adopt stainless steel water Bath and external circulation, the temperature can reach -20 ℃, equipped with pressure/suction pump and Pt100 Sensor, support multi-stage program control and external Communication interface, with hardware overtemperature protection.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030855
Service :The delivery and service By NBCLab.Com
The BC208 bath thermostatic circulator is a thermostatic circulator with heating head. With the help of external circulating water or chilled down liquid tank, the temperature can reach room temperature or -20 ° C. The bath body is made of all stainless steel and filled with aluminum silicate cotton insulation, which provides an economical solution for the sample to be placed directly in the bath for thermostatic test. Optional external circulation adapter and external temperature sensor PT100 can be used for external temperature control and circulation applications, suitable for sample temperature control, material testing, quality control, analysis and other fields.
1. Hardware over-temperature protection, the user can set the protection temperature through the knob, in the case of equipment program failure, it can still be over-temperature protection to avoid dry burning, in line with DIN12876 standard level III, flammability bath liquid can be used. 2. Maintenance-free pressure/suction pump, pump pressure and Flow rate automatically adapt to external load. 3. Optional multi-stage programmable controller, users can achieve multi-stage program control, such as regular heating, cooling, thermostatic, slope and the time of each section, each program can set the running time, the maximum time of each section is 999 hours. 4. Equipped with external temperature sensor interface, optional movable external temperature sensor, with professional PID TAC control technology, Cascade cascade control technology and bath internal and external temperature lock control technology, can accurately control the bath external material temperature. 5. Pt100 temperature sensor, single point, two point and multi point temperature calibrating. 6. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 7. Optional related accessories are available for different internal and external applications. 8. The buzzer can be set to silent or audible. 9. Multiple operation modes are optional, and accidental power failure can be automatically restored. 10. The device serial number can be checked by software. 11. Optional intelligent control functions: a variety of interfaces (RS485, RS232) to achieve remote communication and control the start and stop of equipment. 12. Optional normally open and normally closed 2 external contact points, can be connected to external alarms. 13. Optional set of 12V switch Output signal for controlling external solenoid valve. 14. An optional set of 5V external input switch signals can be used for external smart devices to control the start and stop of the instrument. 15. Optional 0-10V or 4-20mA analog signal input can be used for external smart devices to control the start and stop of the instrument.
The device heats the medium in the bath through the built-in heater, and uses the chill down coil to exchange heat with the external circulating water or chill down tank to achieve cooling, so that the temperature in the tank is precisely controlled within the set range. Its intelligent PID Control system works with the Pt100 temperature sensor to ensure stable temperature. The pressure/suction pump automatically adapts to the external load to achieve the circulation of the medium.
Sample temperature control, material testing, quality control, analysis
DIN 12876 Standard Class III/FL
1. Place the device on a stable countertop and connect it to the power supply. 2. Add an appropriate amount of working medium (such as water or chilling down liquid) to the bath. 3. Connect external circulation lines or options as required. 4. Turn on the power switch and set the target temperature, protection temperature and Miscellaneous operating parameters through the control panel. 5. Start the equipment, the equipment will start heating or chilling down cycle to reach and maintain the set temperature. 6. Place the sample to be tested in the bath or connect it to an external circulation system. 7. After the experiment, power off the device, remove the sample, and drain or clean the bath as needed.
• Power supply voltage (200~ 230VAC/50Hz) meets the requirements before use. • Ambient Temperature of the equipment should be between 5 and 32 ° C, and the relative humidity should not exceed 80%. • Ensure that the liquid level of the bath is sufficient to avoid dry burning. The equipment has liquid level protection and hardware over-temperature protection functions. • When using flammability baths, ensure that the equipment meets DIN 12876 Class III/FL Safety level. • The maximum pressure of the pump is 0.3 bar, and the maximum suction force is 0.2 bar. Please do not use it beyond the limit. Equipment allows for continuous operation (100% load rate), but regular inspections and maintenance are still recommended. Before moving or cleaning equipment, be sure to disconnect the power supply. • Optional accessories (such as external Probes, Programming Controllers, Communication interfaces, etc.) must be installed and used correctly according to the instructions.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.