Temperature range up to -20 ℃ to 150 ℃, temperature control accuracy +/- 0.05~ 0.1K. Adopt pressure/suction pump, Flow rate 22L/min, support external temperature control and circulation, with hardware over-temperature protection, liquid level protection and a variety of safe operation modes.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030860
Service :The delivery and service By NBCLab.Com
The LABTOP BC320E bath thermostatic circulator is a thermostatic circulator with heating head. With the help of external circulating water or chilled down liquid tank, the temperature can reach room temperature or -20 ° C. The bath body is made of all stainless steel and filled with aluminum silicate cotton insulation, providing an economical solution for the sample to be placed directly in the bath for thermostatic testing. Optional external circulation adapter and external temperature sensor PT100 can be used for external temperature control and recycling applications, suitable for sample temperature control, material testing, quality control and chemical analysis.
1. Hardware over-temperature protection, users can set the protection temperature through the knob, in line with DIN12876 standard level III, flammability bath liquid can be used. 2. Maintenance-free pressure/suction pump, pump pressure and Flow rate automatically adapt to external load. 3. Optional multi-segment programmable controller to achieve multi-segment program control, with a maximum duration of 999 hours per segment. 4. Equipped with external temperature sensor interface, with professional PID TAC control technology, Cascade cascade control technology and bath temperature difference lock control technology, can accurately control the temperature of the external material of the bath. 5. Pt100 temperature sensor, single point, two point and multi point temperature calibrating. 6. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 7. Optional related accessories can be used to form different internal and external applications. 8. The buzzer can be set to silent or audible. 9. Multiple operation modes are optional, and accidental power failure can be automatically restored. 10. The device serial number can be queried through the software. 11. Optional intelligent control functions: a variety of interfaces (RS485, RS232) to achieve remote communication and control the start and stop of equipment. 12. Optional normally open and normally closed 2 external contact points, can be connected to external alarms. 13. Optional set of 12V switch Output signal for controlling external solenoid valve. 14. An optional set of 5V external input switch signals can be used for external smart devices to control the start and stop of the instrument. 15. Optional 0-10V or 4-20mA analog signal input can be used for external smart devices to control the start and stop of the instrument.
The device is a thermostatic circulation unit that is heated by a built-in heater and cooled down by means of a chill down coil and an external circulating water or chill down tank, allowing for a wide range of temperature control from room temperature to -20 ° C. Its intelligent PID Control system, combined with the Pt100 temperature sensor, precisely monitors and regulates the temperature in the bath. The pressure/suction pump drives the working medium circulation to ensure uniform and stable temperature.
Sample temperature control, material testing, quality control, chemical analysis
DIN 12876
1. Place the device on a stable countertop and connect it to the power supply. 2. Add an appropriate amount of working medium (water or chilled down liquid) to the Tank. 3. Connect external circulation lines or options as required. 4. Turn on the power supply and set the target temperature, protection temperature and Miscellaneous operating parameters through the control panel. 5. Start the equipment, the pump starts working, and the heating/cooling down system runs to reach and maintain the set temperature. 6. Place the sample to be tested in the bath or connect it to an external circulation system. 7. After the experiment, power off the equipment, remove the sample, and clean the equipment.
• Power supply voltage (200~ 230VAC/50Hz) meets the requirements before use. • Equipment Ambient Temperature should be 5~ 32 ℃, relative humidity ≤ 80%. • Do not touch heating components or high-temperature liquids while the equipment is running to prevent burns. • Ensure that the liquid level in the Tank is sufficient to avoid dry burning. The equipment has liquid level protection and over-temperature protection functions. • If using flammability bath, ensure that the equipment meets Safety level III/FL standards. • The connection interface of the pump is M16x1mm, please ensure that the external piping is tightly connected to prevent leakage. The equipment is allowed to operate continuously, but it is recommended to check the status of the equipment after a long period of operation. • When cleaning and maintaining, please disconnect the power supply and use a suitable detergent to avoid damage to the stainless steel surface and internal components. • When selecting an external Sensor or Communication interface, please refer to the relevant instructions for correct connection and setting.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.