Temperature range -20 ℃ to 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1K, using pressure/suction pump and Pt100 Sensor, support multi-stage program control and external Communication interface.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030861
Service :The delivery and service By NBCLab.Com
The LABTOP BC227E bath thermostatic circulator is a thermostatic circulator with a heating head that can reach room temperature or -20 ° C by chilling down the coil and external circulating water or chilling down the bath. The bath body is made of all stainless steel and filled with aluminum silicate cotton insulation, providing an economical solution for placing the sample directly in the bath for thermostatic testing. Optional external circulation adapter and external temperature sensor PT100 for external temperature control and cycling applications, suitable for sample temperature control, material testing, quality control and analysis.
1. Hardware over-temperature protection, users can set the protection temperature through the knob, and dry burning can still be avoided when the equipment program fails. It meets the DIN12876 standard level III and can use flammability bath liquid. 2. Maintenance-free pressure/suction pump, pump pressure and Flow rate automatically adapt to external load. 3. Optional multi-stage programmable controller, support multi-stage program control, such as regular heating, cooling, thermostatic, slope and each period of time, each program can set the running time, up to 999 hours. 4. Equipped with external temperature sensor interface, optional movable external temperature sensor, combined with PID TAC control technology, Cascade cascade control and bath temperature difference lock control technology, precise control of bath external material temperature. 5. Pt100 temperature sensor, supports single point, two point and multi point temperature calibrating. 6. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 7. Optional related accessories can be used to form different internal and external applications. 8. The buzzer can be set to silent or audible. 9. A variety of operation modes are optional, and accidental power failure can be automatically restored: mode 1 stops normally after power failure, and the setting value can be changed; mode 2 automatically runs after power failure, and the setting value can be changed; mode 3 automatically runs after power failure, and the setting value cannot be changed. 10. The device serial number can be queried through the software. 11. Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication, control equipment start and stop. 12. Optional normally open and normally closed 2 external contact points, connected to the external alarm. 13. Optional set of 12V switch Output signal to control external solenoid valve. 14. Optional set of 5V external input switch signals for external smart devices to control the start and stop of the instrument. 15. Optional 0-10V or 4-20mA analog signal input for external smart devices to control the start and stop of the instrument.
The BC227E bath thermostatic circulator achieves temperature control through a heating head and chill down coil combined with external circulating water or chilled down bath. Temperature range from -20 ° C to 150 ° C. Intelligent PID control technology and Pt100 temperature sensor, combined with optional external temperature sensor and cascade control technology, precisely adjust the temperature inside and outside the bath. The pump system is a pressure/suction pump that automatically adapts to external loads to ensure stable circulation.
Sample temperature control, material testing, quality control, analysis
DIN 12876
1. Connect the power supply to ensure that the Ambient Temperature is within the range of 5~ 32 ° C. Select the operation mode (Mode 1, Mode 2 or Mode 3) as required. 3. Set the temperature parameters and use the knob to set the over-temperature protection. 4. Start the equipment and monitor temperature fluctuations and pump operation status. 5. Optional external Sensor or accessories for extended application. 6. After use, turn off the device according to the specifications.
• Ensure that the Ambient Temperature is within the range of 5~ 32 ° C and the relative humidity does not exceed 80%. • Power supply voltage is 200~ 230VAC/50Hz before use. • Avoid dry burning of equipment and set hardware overtemperature protection. • Optional accessories should be installed correctly to avoid improper operation. Equipment is allowed to operate continuously for 100%, but requires regular maintenance. • When using flammability bath, ensure compliance with safety standards.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.