Please contact customer service
Temperature range up to -20 ℃ to 220 ℃, equipped with hardware over-temperature protection and maintenance-free pressure/suction pump, support multi-stage program control and external Sensor precise temperature control, in line with safety standards.
Category : Thermostatic Bath
Brand : labtop
SKU : NB030866
Service :The delivery and service By NBCLab.Com
The BC220 bath thermostatic circulator is a thermostatic circulator with a heating head. With the help of external circulating water or chilled down liquid tank, the temperature can reach room temperature or -20 ° C. The bath body is made of all stainless steel and filled with aluminum silicate cotton insulation, providing an economical solution for the sample to be placed directly in the bath for thermostatic testing. Optional external circulation adapter and external temperature sensor PT100 can be used for external temperature control and recycling applications, suitable for sample temperature control, material testing, quality control, analysis, etc.
1. Hardware over-temperature protection, the user can set the protection temperature through the knob, in the case of equipment program failure, it can still be over-temperature protection to avoid dry burning, in line with DIN12876 standard level III, flammability bath liquid can be used. 2. Maintenance-free pressure/suction pump, pump pressure and Flow rate automatically adapt to external load. 3. Optional multi-stage programmable controller, the user can realize multi-stage program control, such as regular heating, cooling, thermostatic, slope and each period of time, each program can set the running time, the maximum time of each period is 999 hours. 4. Equipped with external temperature sensor interface, optional movable external temperature sensor, with professional PID TAC control technology, Cascade cascade control technology and bath internal and external temperature lock control technology, can accurately control the bath external material temperature. 5. Pt100 temperature sensor, single point, two point and multi point temperature calibrating. 6. Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics. 7. Optional related accessories are available for different internal and external applications. 8. The buzzer can be set to silent or audible. 9. Multiple operation modes are optional, and accidental power failure can be automatically restored. 10. The device serial number can be checked by software. 11. Optional intelligent control functions: a variety of interfaces (RS485, RS232) to achieve remote communication and control the start and stop of equipment. 12. Optional normally open and normally closed 2 external contact points, can be connected to external alarms. 13. Optional set of 12V switch Output signal for controlling external solenoid valve. 14. An optional set of 5V external input switch signals can be used for external smart devices to control the start and stop of the instrument. 15. Optional 0-10V or 4-20mA analog signal input can be used for external smart devices to control the start and stop of the instrument.
The device is a thermostatic circulation device with a heating head. Temperature range from room temperature to -20 ° C can be achieved with the help of the chill down coil, with the help of external circulating water or chill down tank temperature regulation. Precise temperature control is achieved through intelligent PID control technology and Pt100 temperature sensor, and the pressure/suction pump automatically adapts to the external load to ensure stable circulation.
Sample temperature control, material testing, quality control, analysis
DIN 12876 Standard Class III
1. According to application requirements, optional external circulation adapter, external temperature sensor PT100 or Miscellaneous accessories. 2. Set the hardware overtemperature protection temperature through the knob. 3. Select the operation mode (such as power failure recovery mode) as needed. 4. Optional multi-stage programmable controller for program setting (such as heating, cooling, thermostatic program). Optional external interface (e.g. RS485, RS232) or signal line (e.g. 0-10V, 4-20mA) for remote or external device control. 6. Optional external alarm touch point or solenoid valve control signal.
• Use environmentally friendly natural refrigerants. • The equipment has liquid level protection and over-temperature protection functions. • Safety level III/FL compliant with flammability liquids. • Allows continuous operation: 100%. • Permissible Ambient Temperature: 5~ 32 ℃. • Allowable relative humidity: 80%. • Power supply voltage: 200~ 230VAC/50Hz.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.