Please contact customer service
Imported electrochemistry/infrared Sensor, Measurement accuracy is high and Response is fast. Built-in powerful air pump, can work in micro negative pressure environment, detect 1-5 kinds of gases at the same time, support a variety of concentration units to switch freely.
Category : Gas Detector
Brand : KORNO
SKU : NB032005
Service :The delivery and service By NBCLab.Com
GT-1000-CL2 (0-20ppm) Portable Gas detector is a high-performance testing equipment of KORNO brand, suitable for chlorine concentration detection in various industrial environments and special environments. The instrument adopts imported electrochemistry/infrared absorption gas Sensor and microcontroller technology, and has the characteristics of fast Response speed, high Measurement accuracy, Stability and Repeatability. The performance of the whole machine ranks among the top in China. Built-in 4000mAh large-capacity polymer rechargeable battery, equipped with 3.5-inch full-view IPS industrial color screen, supports functions such as historical data viewing, storage, printing, export and temperature Humidity detection. The operation is simple, and the user can customize the setting of various parameters.
1. Measurement accuracy is high with new semiconductor nano process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip. 2. Adopt 3.5-inch full-view IPS industrial-grade color screen, the resolution is 320x480, and the display is clear. 3. PPM,% VOL, mg/m3, mg/L four concentration units can be freely switched, high and low ranges can be automatically switched. 4. Can simultaneously detect 1-5 kinds of gases, Sensor any combination, support PM2.5 dust particle Sensor, Temperature Humidity Sensor and other Sensors. 5. With Data storage function, a single channel can store 30,800 groups of data, support screen viewing historical data and data export. 6. With data printing function, it can be equipped with a micro printer to print data. 7. With Temperature Humidity detection function, it can detect the temperature Humidity value of gas in the field or pipeline. 8. Multiple modes can be adjusted: detection mode, storage mode, printing mode, display mode, air pump mode. 9. Built-in powerful air pump, can work in a micro negative pressure environment, the air chamber design is reasonable to ensure that the Sensor is not disturbed by pressure. 10. With overvoltage protection, overcharge protection, anti-static interference, anti-magnetic field interference and other functions. 11. Support full software Automatic calibration, Sensor up to 6 target point calibrating, ensure measurement accuracy and linearity, and have data recovery function. 12. Full Chinese/English operation menu, simple and practical. 13. With temperature compensation function, dust-proof, waterproof design, equipped with dust Filter, suitable for various harsh occasions.
The gas detector uses a pump-suction Sampling method to suck the gas to be tested into the inside of the instrument through a built-in powerful air pump. The gas passes through a reasonably designed gas chamber and contacts the built-in imported electrochemistry or infrared absorption gas Sensor. The Sensor converts the gas concentration signal into an electrical signal, which is processed, analyzed and temperature compensated by a 24-bit ADC data collection chip and a 32-bit microprocessor. Finally, the accurate concentration value is displayed in real time on the 3.5-inch IPS industrial color screen. The instrument supports multiple concentration unit conversion and automatic range switching.
Gas concentration detection in various industrial environments and special environments
Explosion-proof mark: ExdII CT4 (intrinsically safe type), Protection Rating: IP65
1. Check whether the Appearance and accessories are in good condition before starting. 2. Press the power button for a long time to turn it on, and the instrument will self-test. 3. Set the detection mode, storage mode, printing mode and other parameters through the Chinese/English menu. 4. Place the sampling Probe in the environment or pipeline to be tested, and start the built-in air pump for sampling detection. 5. Read data such as gas concentration, temperature and Humidity in real time on the 3.5-inch color screen. 6. You can view historical storage data through the menu, or connect a printer for data printing. 7. After the detection is completed, turn off the air pump and exit the detection mode. 8. Connect the computer through the data cable to export the stored data. 9. Turn off the machine after use and charge the instrument in time.
• Do not use under conditions exceeding the Operating Ambient Temperature (-30~ 60 ° C) or Humidity (≤ 95% RH, no condensation). • Do not use in environments beyond the Operating Pressure Range (-30~ 100Kpa). • The instrument is designed to be explosion-proof (ExdII CT4), but should still be avoided in extremely hazardous or open flame environments. Periodically calibrated to ensure measurement accuracy and linearity. • Use the matching charger to charge to avoid overcharging. • Pay attention to protect the instrument to avoid violent impact, static electricity or strong magnetic field interference. • When sampling, make sure the Dust Filter is clean to avoid clogging affecting the detection. • Battery capacity is large, it is recommended to charge and maintain regularly when not in use for a long time.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.