Can simultaneously detect 1-5 kinds of gases, Sensor any combination, Measurement accuracy, Linearity ≤ +/- 1%. Built-in powerful air pump, support micro negative pressure environment work, with Data storage, printing and Humidity detection functions.
Category : Gas Detector
Brand : KORNO
SKU : NB032012
Service :The delivery and service By NBCLab.Com
GT-1000-CL2 (0-5000ppm) Portable Gas detector, suitable for chlorine concentration detection in various industrial environments and special environments. The instrument adopts imported electrochemistry/infrared absorption gas Sensor and microcontroller technology, with fast Response speed, high Measurement accuracy, good Stability and Repeatability, and the whole machine performance ranks among the top in China. Built-in 4000mA large-capacity polymer rechargeable battery, adopts 3.5-inch full-view IPS industrial color screen, with Data storage, printing, export and Temperature and Humidity detection functions, simple operation, users can customize various parameters according to their needs.
1. Using new semiconductor nano process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip, Measurement accuracy is high. 2. Adopt 3.5-inch full-view IPS industrial-grade color screen, the resolution is 320x480, and the display is clear and intuitive. 3. PPM,% VOL, mg/m3, mg/L four concentration units can be freely switched, high and low ranges can be automatically switched. 4. Can detect 1-5 kinds of gases at the same time, Sensor supports any combination, compatible with PM2.5 dust particle Sensor, Temperature Humidity Sensor and other types. 5. With Data storage function, a single channel can store 30,800 sets of data, and supports viewing historical data and exporting data on the screen. 6. With data printing function, it can be connected to a micro printer to print data. 7. With Temperature and Humidity detection function, it can detect the temperature and Humidity value of gas in the field or pipeline. 8. Multiple Operating Modes adjustable, including detection mode, storage mode, printing mode, display mode, air pump mode. 9. Built-in powerful air pump, can work in a micro negative pressure environment, the air chamber design is reasonable, can ensure that the Sensor is not disturbed by pressure. 10. With overvoltage protection, overcharge protection, anti-static interference, anti-magnetic field interference and other functions. 11. Support full software Automatic calibration, Sensor has up to 6 target point Adjustment, to ensure the accuracy and linearity of measurement, and has data recovery function. 12. Provide full Chinese/English operation menu, simple and practical. 13. With temperature compensation function, dust-proof, waterproof design, equipped with dust Filter, suitable for various harsh occasions.
The gas detector uses a pump-suction Sampling method, with a built-in powerful air pump to suck the gas to be tested into the air chamber inside the instrument. The core of the instrument adopts an imported gas Sensor based on electrochemistry or infrared absorption principle. When the target gas (such as chlorine) comes into contact with the Sensor, it will generate an electrical signal or Optical inspection signal change proportional to the gas concentration. The signal is processed and converted by a microprocessor and a 24-bit ADC data collection chip for High Accuracy, and finally the gas concentration value is displayed on the screen in real time. The instrument has a temperature compensation function to correct the impact of Ambient Temperature on the measurement result to ensure accurate data.
Suitable for gas concentration detection in various industrial environments and special environments.
Explosion-proof mark: ExdII CT4 (intrinsically safe type), Protection Rating: IP65
1. Boot inspection: Make sure that the instrument has sufficient power, and turn it on for self-inspection. 2. Mode settings: According to the detection requirements, set the detection mode, storage mode, printing mode, display mode, air pump mode, etc. through the menu. 3.Calibrate: Full software Automatic calibration or 6-level target point calibrating with standard gas as required. 4. Sampling detection: Start the built-in air pump and place the sampling Probe in the environment to be tested for gas sampling. 5. Reading recording: Read the gas concentration in real time on the 3.5-inch IPS color screen (the unit can be switched), and choose to store the data. 6. Data management: You can view historical data on the instrument screen, or transfer it to an external device through the data export function, or connect a micro printer to print data. 7. Shut down: After the test is completed, turn off the instrument.
• Please use it in the working environment specified by the instrument (temperature -30~ 60 ℃, Humidity ≤ 95% RH without condensation, air pressure -30~ 100Kpa). • Avoid use in hazardous locations that exceed the Explosion-proof level. • Regularly calibrate the instrument to ensure measurement accuracy. • Pay attention to the instrument's Protection Rating (IP65), but still avoid prolonged immersion or strong Impacts. • Use the matching charger to charge the built-in polymer battery, and pay attention to the overcharge protection function. • When sampling, make sure the air path is clear and the dust Filter is clean to ensure that the Sensor is free from contamination and pressure interference. • The instrument has a data recovery function, but it is recommended to export important data regularly for backup. • Please follow the menu guidelines when operating to avoid misoperation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.