Please contact customer service
Using imported electrochemistry/infrared Sensor and 32-bit microprocessor, Measurement accuracy is leading in the industry. Supports simultaneous detection of 1-5 kinds of gases, unit free switching, built-in powerful air pump, can work in micro negative pressure environment, with Data storage, printing, Humidity detection and overvoltage protection and other multiple functions.
Category : Gas Detector
Brand : KORNO
SKU : NB032020
Service :The delivery and service By NBCLab.Com
GT-1000-CO (0-100ppm) Portable Gas detector is a high-performance detection equipment of KORNO brand, which is suitable for carbon monoxide gas concentration detection in various industrial environments and special environments. The instrument adopts imported electrochemistry/infrared absorption gas Sensor and microcontroller technology, and has the characteristics of fast Response speed, high Measurement accuracy, Stability and Repeatability. The performance of the whole machine ranks among the top in China. Built-in 4000mAh large capacity polymer rechargeable battery, long battery life; equipped with 3.5 inch full view IPS industrial color screen, can clearly display technical indicators, gas concentration value, historical data, and integrates Data storage, printing, export and Humidity detection and other functions.
Measurement accuracy is the highest in the industry with a new semiconductor nano process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip. Adopt 3.5-inch full-view IPS industrial-grade color screen (resolution 320x480) to clearly display various technical indicators and gas concentration values. 3. The four concentration units of PPM,% VOL, mg/m ³, mg/L can be freely switched, and the high and low ranges can be automatically switched. 4. Can detect 1-5 kinds of gases at the same time, Sensor supports any combination, compatible with PM2.5 dust particle Sensor, Temperature Humidity Sensor and other types of Sensors. 5. Data storage function (30,800 sets of data can be stored in a single channel), support screen viewing historical data and data export; data printing function, can be connected to a micro printer; Humidity detection function. 6. Multiple modes are adjustable, including detection mode, storage mode, printing mode, display mode, air pump mode. 7. Built-in powerful air pump, can work in a micro negative pressure environment, the air chamber design is reasonable, can ensure that the Sensor is not disturbed by pressure. 8. With overvoltage protection, overcharge protection, anti-static interference, anti-magnetic field interference and other functions. 9. Support Full Software Automatic calibration, Sensor has up to 6 target point Adjustment, to ensure measurement accuracy and linearity, and has data recovery function. 10. Provide full Chinese/English operation menu, simple and practical. 11. With temperature compensation function, dust-proof, waterproof design, equipped with dust Filter, suitable for various harsh occasions.
The gas detector uses a pump-suction Sampling method to suck environment gases into the air chamber inside the instrument through a built-in powerful air pump. The gas is in contact with the built-in inlet electrochemistry or infrared absorption gas Sensor, which generates corresponding electrical signals according to the concentration of the target gas. These signals are converted into digital signals by a 24-bit ADC data collection chip and processed, analyzed and temperature compensated by an ultra-low power 32-bit microprocessor. Finally, the accurate gas concentration value (supporting PPM,% VOL, mg/m ³, mg/L multiple units) is displayed in real time on the 3.5-inch IPS industrial color screen. Instrument through the microcontroller technology implementation Fast Response, High Accuracy measurement and a variety of intelligent control functions.
Gas concentration detection in various industrial environments and special environments
Explosion-proof mark: ExdII CT4 (intrinsically safe type), Protection Rating: IP65
1. Check before starting: Ensure that the instrument has sufficient power, Sensor and Filter are installed correctly, and Appearance is not damaged. 2. Boot and self-test: Long press the power button to turn it on, the instrument will perform self-test, and the screen displays the start interface and the preheating status of the Sensor. 3. Mode setting: Enter the setting interface through the menu key, and set the detection mode, storage mode (real-time/timing), printing mode, display mode, air pump mode, etc. according to the detection requirements. 4. Calibrate (if required): Use standard gas, enter the calibrate program through the menu, and calibrate according to the prompts for zero or span (support up to 6 levels of target point calibrate). 5. Start detection: Place the sampling Probe in the environment to be tested, the built-in air pump of the instrument will automatically extract the gas for detection, and the real-time concentration value will be displayed on the main screen. 6. Data viewing and export: During or after the detection process, the stored historical data can be viewed through the menu, and the data can be exported by connecting to the computer through the data cable. 7. Print data (if required): Connect the micro printer and select print historical data or real-time data through the menu. 8. Shutdown and charging: After the detection is completed, shut down and save. When the power is insufficient, use the matching charger to charge.
• Do not use under conditions exceeding the Operating Ambient Temperature (-30~ 60 ° C) or Humidity (≤ 95% RH, no condensation). • Operating Pressure range of -30~ 100Kpa, do not use in pressure environment beyond this range, so as not to damage the Sensor or air pump. • The instrument has an explosion-proof mark (ExdII CT4), but it should still be avoided in hazardous locations beyond its explosion-proof level. When calibrating, be sure to use a known concentration of standard gas and ensure a stable environment to ensure calibrating accuracy. • The built-in battery is a polymer rechargeable battery, please use the original or designated charger to avoid overcharging and overdischarging. • The instrument adopts a dustproof and waterproof design (IP65), but after long-term use in harsh environments (such as high dust), it is recommended to clean or replace the dust filter regularly. • Avoid strong static electricity and magnetic field interference to the instrument, so as not to affect the Measurement accuracy. • When using the air pump function in a micro-negative pressure environment, please pay attention to the load capacity of the pump to avoid long-term overload operation. • The instrument shell is made of ABS + PC material, please avoid severe impact or contact with corrosion chemicals. • When users customize setting parameters, please make sure to understand the meaning of the parameters. Wrong settings may affect instrument performance or measurement results.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.