Using High Accuracy Sensor and Microprocessor, Measurement accuracy of +/- 2%, Response Time ≤ 20s. Can detect 1-5 gases at the same time, support a variety of Unit switches, built-in powerful pump, with Data storage, printing and Humidity detection functions.
Category : Gas Detector
Brand : KORNO
SKU : NB032029
Service :The delivery and service By NBCLab.Com
GT-1000-CO2 (0-10000ppm) Portable Gas detector is a product under the KORNO brand, suitable for gas concentration detection in various industrial environments and special environments. The instrument adopts China electrochemistry/infrared absorption gas Sensor and microcontroller technology, and has the characteristics of fast Response speed, high Measurement accuracy, good Stability and Repeatability, etc. The whole machine performance ranks among the top in China. Built-in 4000mA large-capacity polymer rechargeable battery, adopts 3.5-inch full-view IPS industrial color screen, supports functions such as Data storage, printing, export and temperature and Humidity detection. The operation is simple, and the user can customize various parameters.
1. Measurement accuracy is high with new semiconductor nano process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip. 2. Adopt 3.5-inch full-view IPS industrial-grade color screen, the resolution is 320x480, and the display is clear. 3. PPM,% VOL, mg/m3, mg/L four concentration units can be freely switched, high and low ranges can be automatically switched. 4. Can simultaneously detect 1-5 kinds of gases, Sensor any combination, support PM2.5 dust particle Sensor, Temperature Humidity Sensor and other Sensors. 5. With Data storage function (single channel 30800 group), you can view historical data on the screen, support data export and micro printer printing. 6. With Temperature Humidity detection function, it can detect the temperature Humidity value of gas in the field or pipeline. 7. A variety of modes can be adjusted, including detection mode, storage mode, printing mode, display mode, air pump mode. 8. Built-in powerful air pump, can work in a micro negative pressure environment, the air chamber design is reasonable to ensure that the Sensor is not disturbed by pressure. 9. With overvoltage protection, overcharge protection, anti-static interference, anti-magnetic field interference and other functions. 10. Support Full Software Automatic calibration, Sensor up to 6 target points calibrated to ensure measurement accuracy and linearity, and with data recovery function. 11. Provide full Chinese/English operation menu, simple and practical. 12. With temperature compensation function, dust-proof, waterproof design, equipped with dust Filter, suitable for various harsh occasions.
The gas detector uses a pump-suction Sampling method to suck environment gases into the air chamber inside the instrument through a built-in powerful air pump. The core of the instrument uses China electrochemistry or infrared absorption gas Sensor, combined with a new semiconductor nano-process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip, for High Accuracy measurement and analysis of gas concentration. Measurement results are displayed in real time through a 3.5-inch IPS industrial color screen, and can be used for Data storage or processing according to settings.
Various industrial environments, special environments
Explosion-proof marking: ExdII CT4 (intrinsically safe type)
1. Turn on the instrument. 2. Perform various parameter settings (such as detection mode, storage mode, etc.) through the full Chinese/English menu. 3. Use the built-in air pump for gas sampling. 4. Read gas concentration and Temperature Humidity data in real time on the screen. 5. You can choose to view historical storage data. 6. Export data or connect a micro printer to print data as needed. 7. Shut down after use.
• Please use within the range of Ambient Temperature (-30~ 60 ℃) and Humidity (≤ 95% RH, no condensation) of the instrument. • Operating Pressure range is -30~ 100Kpa, please make sure to operate under the allowable air pressure environment. • Instrument Protection Rating is IP65, but care should be taken to avoid irreversible damage to the instrument in extremely harsh environments. • Please use the specified 4000mA rechargeable polymer battery and pay attention to the overcharge protection function to avoid improper charging. • When calibrating, follow the full software Automatic calibration and 6-level target point calibrating procedure to ensure measurement accuracy. • The instrument is equipped with a dust Filter, make sure the Filter is effective when used in a dust environment and clean or replace as needed. Although it has anti-static and anti-magnetic field interference functions, it should still be avoided near strong sources of interference. • Net weight of the instrument is 0.5Kg and the size is 220 * 85 * 55mm. Please pay attention to avoid violent impact when carrying and storing. • This instrument is designed to be explosion-proof (ExdII CT4), but still needs to be used with caution in hazardous environments that meet explosion-proof requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.