Imported electrochemistry/infrared Sensor, Measurement accuracy ≤ +/- 3%, Response Time ≤ 20s. Supports simultaneous detection of 1-5 gases, Sensor can be combined arbitrarily, built-in powerful air pump, with data storage, printing, export and temperature and humidity detection functions, Protection Rating IP65, suitable for harsh environments.
Category : Gas Detector
Brand : KORNO
SKU : NB032072
Service :The delivery and service By NBCLab.Com
GT1000-Portable Gas detector, suitable for gas concentration detection in various industrial environments and special environments, adopts imported electrochemistry/infrared absorption gas Sensor and microcontroller technology, Fast Response Speed, High Measurement Accuracy, Good Stability and Repeatability. The instrument has a built-in 4000mA large-capacity polymer rechargeable battery, adopts a 3.5-inch full-view IPS industrial color screen, and has functions such as data storage, printing, export and temperature and humidity detection.
1. Using semiconductor nano process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip, Measurement accuracy is high. 2. Adopt 3.5-inch full-view IPS industrial-grade color screen, the resolution is 320x480, and the display is clear. 3. PPM,% VOL, mg/m3, mg/L four concentration units can be freely switched, high and low ranges can be automatically switched. 4. Can simultaneously detect 1-5 kinds of gases, Sensor any combination, support PM2.5 dust particle Sensor, temperature and humidity Sensor and other Sensors. 5. With data storage function, a single channel can store 30,800 sets of data, and supports on-screen viewing of historical data and data export. 6. With data printing function, it can be equipped with a micro printer to print data. 7. With temperature and humidity detection function, it can detect the temperature and humidity value of gas in the field or pipeline. 8. The detection mode, storage mode, printing mode, display mode, air pump mode and other modes can be adjusted. 9. Built-in powerful air pump, can work in a micro negative pressure environment, the air chamber design is reasonable to ensure that the Sensor is not disturbed by pressure. 10. With overvoltage protection, overcharge protection, anti-static interference, anti-magnetic field interference and other functions. 11. Support full software Automatic calibration, Sensor has up to 6 levels of target point Adjustment to ensure measurement accuracy and linearity, and has data recovery function. 12. Support full Chinese/English operation menu. 13. With temperature compensation function, dust-proof, waterproof design, equipped with dust Filter, suitable for various harsh occasions.
The instrument adopts pump-suction Sampling method with built-in powerful suction pump to suck the gas to be measured into the detection gas chamber. The specific gas concentration is sensed through the imported electrochemistry or infrared absorption gas Sensor, and the signal is transmitted to the microcontroller. The microcontroller processes and calculates the signal, and finally displays the gas concentration value and Miscellaneous parameters on the screen.
Various industrial environments, special environments
Explosion-proof marking: ExdII CT4 (intrinsically safe type)
1. Boot self-test. 2. According to the menu prompts, set the detection mode, storage mode and other parameters. 3. Place the sampling probe in the environment or pipeline to be tested. 4. The instrument automatically pumps sampling and displays gas concentration and temperature and humidity values in real time. 5. You can view historical data through the screen, or connect the printer to print data. 6. After use, turn off and charge.
• Please use within the range of instrument working environment temperature (-30~ 60 ℃) and humidity (≤ 95% RH, no condensation). • The working air pressure range is -30~ 100Kpa, please do not use it in a pressure environment beyond this range. • Instrument Protection Rating is IP65, but care should be taken to avoid long-term immersion or strong water flow Impact. • Please use the original matching charger for charging to avoid the risk of overcharging. Periodically calibrated to ensure measurement accuracy. • When used in a potentially explosive environment, ensure that the instrument explosion protection mark (ExdII CT4) meets the on-site explosion protection requirements. • Do not disassemble or modify the instrument yourself. • When not in use for a long time, please charge it regularly to maintain battery performance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.