Please contact customer service
Using imported electrochemistry/infrared Sensor, Measurement accuracy leading in the industry. Can detect 1-5 kinds of gases at the same time, support any combination of Sensor and temperature and humidity detection, built-in powerful air pump, suitable for micro negative pressure environment.
Category : Gas Detector
Brand : KORNO
SKU : NB032107
Service :The delivery and service By NBCLab.Com
GT1000-Portable Gas detector is a high-performance detection equipment of KORNO brand, suitable for gas concentration detection in various industrial environments and special environments. It adopts imported electrochemistry/infrared absorption gas Sensor and microcontroller technology, and has the characteristics of fast Response speed, high Measurement accuracy, Stability and Repeatability. The whole machine performance ranks among the top in China. The instrument has a built-in 4000mA large-capacity polymer rechargeable battery, long standby time, and is equipped with a 3.5-inch full-view IPS industrial color screen, which can clearly display various technical indicators and gas concentration values. It supports historical data viewing, storage, printing, export and temperature and humidity detection functions.
Measurement accuracy is the highest in the industry with a new semiconductor nano process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip. 2. Adopt 3.5-inch full-view IPS industrial-grade color screen with a resolution of 320x480, which clearly displays technical indicators and gas concentration values. 3. PPM,% VOL, mg/m3, mg/L four concentration units can be freely switched, high and low ranges can be automatically switched. 4. Can simultaneously detect 1-5 kinds of gases, Sensor any combination, support PM2.5 dust particle Sensor, temperature and humidity Sensor and other Sensors. 5. With data storage function, a single channel can store 30,800 sets of data, allowing historical data to be visually viewed on the screen, and supporting data export and micro-printer printing. 6. With temperature and humidity detection function, it can detect the temperature and humidity value of gas in the field or pipeline. 7. Various modes can be adjusted, including detection mode, storage mode, printing mode, display mode, air pump mode. 8. Built-in powerful air pump, can work in a micro negative pressure environment, the air chamber design is reasonable to ensure that the Sensor is not disturbed by pressure. 9. With overvoltage protection, overcharge protection, anti-static interference, anti-magnetic field interference and other functions. 10. Support full software Automatic calibration, Sensor has up to 6 levels of target point Adjustment to ensure the accuracy and linearity of measurement, and has data recovery function. 11. Provide full Chinese/English operation menu, simple and practical. 12. With temperature compensation function, dust-proof, waterproof design, equipped with dust Filter, suitable for various harsh occasions.
The portable Gas detector uses the pump-suction Sampling method, which sucks the gas to be tested into the inside of the instrument through a built-in powerful air pump. After the gas enters, it is detected by an imported electrochemistry or infrared absorption gas Sensor, which converts the gas concentration signal into an electrical signal. The microcontroller (using an ultra-low power 32-bit microprocessor) and a 24-bit ADC data collection chip process and analyze the signal at high speed and High Accuracy. Finally, the measurement results (such as NO gas concentration) and temperature and humidity data are displayed in real time on the 3.5-inch IPS industrial color screen. Automatic calibration and temperature compensation ensure measurement accuracy in different environments.
Various industrial environments, special environments
Explosion-proof marking: ExdII CT4 (intrinsically safe type)
1. Boot preparation: Ensure that the instrument has sufficient power, and install and combine the required gas Sensor on the instrument as required. 2. Boot and self-test: Turn on the instrument power supply, and the system will perform self-test to confirm that the Sensor and various functions are normal. 3. Mode settings: Through the Chinese/English operation menu, set the detection mode, storage mode (real-time or timing), printing mode, display mode and air pump mode as needed. 4. calibrate (if required): Sensor calibrate up to 6 target points using full software Automatic calibration function to ensure measurement accuracy. 5. Start testing: place the sampling probe of the instrument in the environment or pipeline to be tested, and the built-in air pump will suck gas for testing. 6. Read the data: View the gas concentration value in real time on the 3.5-inch IPS color screen (the unit can be switched between PPM,% VOL, mg/m3, mg/L) and temperature and humidity information. 7. Data management: You can directly view the stored historical data on the screen, or export the data through the data export function, or connect a micro printer for data printing. 8. Shutdown and Maintenance: Turn off the power after the test is completed, clean the instrument and dust filter regularly, and store it under suitable conditions.
* Do not use the instrument under conditions exceeding the working environment temperature (-30~ 60 ° C) or humidity (≤ 95% RH, no condensation). * The working air pressure range of the instrument is -30~ 100Kpa, please do not use it in a pressure environment beyond this range. Pay attention to the explosion-proof marking of the instrument (ExdII CT4), and use it in hazardous locations that meet its explosion-proof rating requirements. * Instrument Protection Rating is IP65, with certain dustproof and waterproof capabilities, but still need to avoid long-term immersion or strong water spray. * Before use, please ensure that the Sensor type and range (such as NO: 0~ 500ppm) meet the requirements of the gas to be tested. Sensors are regularly calibrated to ensure accuracy and linearity of measurement data. * Built-in 4000mA rechargeable polymer battery, please use the matching charger to charge, and pay attention to the overcharge protection function. The instrument is equipped with a dust filter. When using it in dusty and harsh situations, it is necessary to check and clean or replace the filter. Avoid strong static electricity or magnetic field interference in the instrument, so as not to affect normal testing. * When using the air pump function in a micro-negative pressure environment, please ensure that the air path connection is well sealed. * Net weight of the instrument is 0.5Kg, Dimension 220 * 85 * 55mm, please keep it properly to avoid falling or violent impact.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
