Please contact customer service
Using imported electrochemistry/infrared Sensor, Measurement accuracy ≤ +/- 3%, Response Time ≤ 20 seconds. Supports simultaneous detection of 1-5 kinds of gases, built-in powerful air pump, with data storage, printing, temperature and humidity detection and a variety of protection functions.
Category : Gas Detector
Brand : KORNO
SKU : NB032127
Service :The delivery and service By NBCLab.Com
GT-1000-O3 (0-10ppm) Portable Gas detector is a product under the KORNO brand, which is suitable for ozone (O3) gas concentration detection in various industrial environments and special environments. The instrument adopts imported electrochemistry/infrared absorption gas Sensor and microcontroller technology, and has the characteristics of fast Response speed, high Measurement accuracy, Stability and Repeatability. The performance of the whole machine ranks among the top in China. Built-in 4000mAh large-capacity polymer rechargeable battery, equipped with a 3.5-inch full-view IPS industrial color screen, supports functions such as historical data viewing, storage, printing, export and temperature and humidity detection. The operation is simple, and users can customize various parameters according to their needs.
1. Using new semiconductor nano process ultra-low power 32-bit microprocessor and 24-bit ADC data collection chip, Measurement accuracy is high. 2. Adopt 3.5-inch full-view IPS industrial-grade color screen (resolution 320x480), the display is clear and intuitive. 3. The four concentration units of PPM,% VOL, mg/m ³, mg/L can be freely switched, and the high and low ranges can be automatically switched. 4. Can detect 1-5 kinds of gases at the same time, Sensor supports any combination, compatible with PM2.5 dust particle Sensor, temperature and humidity Sensor and other types. 5. With data storage function (30,800 sets of data can be stored in a single channel), it supports screen viewing of historical data, data export, and micro-printer printing. 6. Equipped with temperature and humidity detection function, it can detect the temperature and humidity value of gas in the field or pipeline. 7. A variety of modes can be adjusted, including detection mode, storage mode, printing mode, display mode, air pump mode. 8. Built-in powerful air pump, can work in a micro negative pressure environment, the air chamber design is reasonable, can ensure that the Sensor is not disturbed by pressure. 9. With overvoltage protection, overcharge protection, anti-static interference, anti-magnetic field interference and other functions. 10. Support full software Automatic calibration, Sensor provides up to 6 levels of target point Adjustment to ensure measurement accuracy and linearity, and has data recovery function. 11. Provide full Chinese/English operation menu, simple and practical. 12. With temperature compensation function, dust-proof, waterproof design, equipped with dust Filter, suitable for various harsh occasions.
The gas detector uses a pump-suction Sampling method, which sucks environment gases into the air chamber inside the instrument through a built-in powerful air pump. The core of the instrument uses an imported electrochemistry or infrared absorption gas Sensor, combined with microcontroller technology, to detect and analyze gas concentration. The Sensor converts the gas concentration signal into an electrical signal, which is processed by a 24-bit ADC data collection chip and a high-performance 32-bit microprocessor, and finally displays the exact concentration value on the screen, and supports functions such as data storage, printing and export.
Suitable for gas concentration detection in various industrial environments and special environments.
Explosion-proof mark: ExdII CT4 (intrinsically safe type), Protection Rating: IP65
1. Boot check: Make sure that the instrument has sufficient power, and check whether the screen display and various functions are normal after booting. 2. Mode settings: According to the detection requirements, set the corresponding detection mode, storage mode, printing mode, display mode and air pump mode in the menu. 3. Calibrate and unit selection: Use the full software Automatic calibration function to calibrate the target point up to 6 levels if necessary. Select the desired concentration unit (PPM,% VOL, mg/m ³, mg/L) in the settings. 4. Start detection: align the instrument sampling port with the gas area to be measured, and start the built-in air pump for pumping sampling. 5. Data reading and recording: Read the gas concentration and temperature and humidity value in real time on the 3.5-inch IPS color screen, and the instrument will automatically or store the data according to the settings. 6. Data management: You can view historical data records on the screen, transfer data through the data export function, or connect a micro printer to print data. 7. Shutdown and maintenance: After the inspection is completed, shut down and perform regular cleaning and maintenance to ensure the normal operation of the Sensor and Filter.
• Please read the instructions carefully before use to ensure that it operates in the working environment specified by the instrument (temperature -30~ 60 ° C, humidity ≤ 95% RH without condensation, air pressure -30~ 100Kpa). • The instrument is designed to be explosion-proof (ExdII CT4), but it is still necessary to avoid use in hazardous environments beyond the explosion protection level. • Note that the Protection Rating of the instrument is IP65, which can be dustproof and waterproof, but still need to avoid long-term immersion or strong Impact. • Battery capacity is large, please use the matching charger when charging, and pay attention to the overcharge protection function to avoid improper charging. When calibrating, make sure to use standard gas and operate in a safe environment to ensure measurement accuracy. • When sampling, please ensure that the gas path is unobstructed and the dust Filter is clean to avoid blockage affecting the sampling effect and Sensor life. • The instrument has a data recovery function, but it is recommended to export important data regularly for backup. • If not used for a long time, please charge the instrument regularly and store the instrument in a drying, non-corrosive gas environment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.