Overview
XTL-3230 Transmittent reflection Polarizing Microscope is a required instrument for the research and identification of birefringent substances by using the polarization characteristics of light. It can be used for single polarized observation, orthogonal polarized observation and cone light observation. It is widely used in research and inspection in geology, chemical industry and other fields. It can also be used for crystal phase observation of liquid polymer materials, biological polymers and liquid crystal materials. It is a suitable instrument for research and teaching in scientific research institutions and universities.
Features
1. Optical inspection system and Modular function design
2. Configuration Infinity stress-free long working distance flat field objective
3. Wide-angle flat-field eyepiece: field of view diameter < 22mm
4. Coarse fretting coaxial focusing mechanism, coarse elastic adjustable, with limit locking device, fretting grid value: 2μm
5. Polarizing observation device can be moved in or out of the optical path, both polarizer and detector can be 360 ° swirl/spin
6. Swirl/spin stage, 360 ° Graduation, vernier grid value 6 ', adjustable center, with locking device, table vertical effective Travel up to 30mm
7. Wide voltage power supply (85-265V 50/60Hz), 6V30W halogen lighting, adjustable luminance
8. The three-eyeliner barrel can freely switch between visual observation and microphotography, and can be 100% transparent during photography, suitable for low-light microscopic image shooting
Principle
XTL-3230 Transmittent reflection Polarizing Microscope uses the polarization characteristics of light to study and identify birefringent substances, and realizes single-polarized observation, orthogonal polarized observation and cone light observation through the combination of polarizer and analyzer.
Applications
Crystal phase observation of geology, chemical industry, liquid polymer materials, biological polymers, liquid crystal materials, scientific research institutions, colleges and universities
Steps
1. Turn on the power and adjust the lighting luminance
2. Move in or out of the polarized viewing device as required
3. swirl/spin polarizer and detector to desired angle
4. Use coarse fretting coaxial focusing mechanism for focusing
5. Rotate the stage for sample observation
6. Switch the visual observation or microphotography mode through the three-eyed lens barrel
Notice
• Power supply voltage in 85-265V range before use
• Pay attention to rough and elastic adjustment when focusing to avoid damage to the sample
• Pay attention to the use of the locking device when rotating the stage
• Pay attention to the working distance when using spring objectives to avoid collisions
• Make sure the triocular barrel is switched to 100% light transmission mode when shooting