Overview
PINGXUAN DC3006-II high and low temperature Thermostatic bath is a device that provides precise hot and cold constant field sources for scientific research and production. It is widely used in Petrochemicals, electronic instrumentation, bioengineering, food physical property testing and chemical analysis, etc., for constant temperature experiments or tests on samples or products, and can also be used as direct or auxiliary heat and cold sources.
Features
1. Adopt self-developed special software and High Accuracy PT100 Sensor, and cooperate with imported electronic components to achieve accurate temperature control.
2. The software system supports temperature correction, with resolution up to 0.01 ° C to ensure accurate display temperature.
3. With over-temperature protection and alarm function, the alarm temperature can be set, and the load can be automatically cut off when the temperature is exceeded.
4. Intelligent PID control system can automatically adjust parameters to ensure strong Temperature Stability, special users can also adjust manually.
5. Software digital locking function to prevent misoperation and ensure the accuracy of experimental data.
6. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
7. Have a professional domestic circulation system to ensure that the temperature in the tank is uniform and stable, and the external circulation system can establish a second thermostatic field outside the machine or as a cold source.
Principle
The device monitors the temperature in the working tank in real time through the High Accuracy temperature sensor (PT100), and feeds the signal back to the intelligent PID control system. The control system drives the refrigeration system (fully enclosed Compressor) or heating system to work, so that the temperature of the medium in the tank quickly reaches and stabilizes at the set value. At the same time, the domestic circulation pump circulates the liquid in the tank to ensure uniform temperature; the external circulation pump can output the thermostatic liquid for the thermostatic or chill down of the external experimental container.
Applications
Research departments of petroleum, chemical industry, electronic instrumentation, physics, chemistry, biological engineering, life science, light industry food property testing, chemical analysis, etc., colleges and universities, enterprise Quality control and production departments
Steps
1. Turn on the power supply and turn on the device.
2. Set the required target temperature and Miscellaneous parameters through the control panel.
3. Start the refrigeration or heating system and the circulating pump, and the equipment starts to work.
4. Monitor and display the temperature. After it stabilizes at the set value, experiments or tests can be carried out.
5. After use, press the "Power" button to turn off the function of the instrument, but the instrument will still display the natural change process of the temperature in the tank.
Notice
Make sure the equipment is placed in a smooth and well-ventilated environment before use.
• Do not allow unrelated personnel to operate the control panel, so as not to affect the experimental data by mistake.
• Pay attention to the Temperature range marked on the device (-30~ 160 ℃), do not use beyond the range.
• When the over-temperature alarm is triggered, please check and troubleshoot in time.
• Regularly check whether the circulation pipeline is smooth to ensure that the internal and external circulation work normally.
• After the equipment is turned off, the display panel will still work and display the residual temperature in the tank. Please pay attention to distinguish.