Overview
PINGXUAN Px-10A standard thermostatic verification tank is a High Accuracy temperature control equipment, mainly used by the Measurement Department to verify the first and second standard mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermistor, standard copper-constantan Thermocouple, and can also be used as a High Accuracy heat source or cold source for production and scientific research.
Features
1. Using dedicated software to develop self-made temperature control technology, equipped with High Accuracy PT100 and all imported electronic components.
2. The software system supports temperature correction with resolution up to 0.001 ° C to ensure accurate display temperature.
3. With over-temperature protection, over-temperature tweet alarm function, can set the alarm temperature, over-temperature automatically cut off the load.
4. Intelligent Software Temperature Stability, PID can automatically adjust parameters according to the medium, also supports manual adjustment.
5. Use software to digitally lock the control system settings to prevent unrelated personnel from misusing and ensure that the experimental data is correct.
6. Accurate temperature control allows for rapid and stable temperature in the working tank.
7. Equipped with an effective fully enclosed Compressor for refrigeration, with fast cooling speed and multiple protections for overheating and overcurrent.
8. Press the "Power" button to turn off all functions of the instrument.
Principle
The equipment is controlled by special software technology and High Accuracy PT100 temperature sensor, combined with all imported electronic components to form an intelligent temperature control system. The system adopts PID algorithm, which can automatically or manually adjust the optimal control parameters according to the medium in the working tank to achieve fast and stable temperature adjustment. The refrigeration system is driven by a fully enclosed Compressor to achieve rapid cooling and ensure safe operation through multiple protection mechanisms.
Applications
Measurement verification, production, scientific research
Steps
1. Turn on the power supply and turn on the device.
2. Set the required temperature and over-temperature alarm temperature through the software system.
3. Put the sample to be verified or tested into the working tank.
4. Start the temperature control program, and the device will automatically adjust to the set temperature and maintain stability.
5. After use, press the "Power" button to turn off all functions.
Notice
• Avoid unrelated personnel operation, please confirm that the setting value has been locked by the software before the experiment.
• Pay attention to the setting and status of the over-temperature alarm function to ensure that the equipment operates within a safe Temperature range.
Please check whether the refrigeration system and electrical protection function are normal before use.
• Do not exceed the specified Temperature range (-10~ 100 ℃).