Overview
PINGXUAN Px-10200A-II standard verification High and low temperature Thermostatic bath is a High Accuracy temperature control device, mainly used for Measurement department verification of first and second class mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermistor, standard copper-constantan Thermocouple, can also be used as High Accuracy heat source or cold source for production and scientific research.
Features
1. Self-made temperature control technology developed by dedicated software, equipped with High Accuracy PT100 Sensor and imported electronic components.
2. The software system supports temperature error correction, and the correction resolution is up to 0.001 ° C to ensure that the display temperature is accurate.
3. With over-temperature protection and alarm function, the alarm temperature can be set, and the load can be automatically cut off when the temperature is exceeded.
4. Intelligent Software Temperature Stability, PID can automatically adjust the best parameters according to different media, and also supports manual adjustment.
5. The software digital locking function can lock various setting values to prevent unrelated personnel from misusing and ensure that the experimental data is correct.
6. Accurate temperature control allows for rapid and stable temperature in the working tank.
7. Equipped with a fully enclosed Compressor refrigeration system, with fast cooling speed and multiple protections for overheating and overcurrent.
8. Press the "Power" button to turn off all functions of the instrument.
Principle
The device is controlled by a dedicated software system combined with a High Accuracy PT100 temperature sensor to monitor the temperature in the working tank in real time. The intelligent PID algorithm automatically or manually adjusts the output power of the heating and cooling system according to the deviation of the set temperature and the measured temperature to achieve fast and accurate temperature control and stabilize the temperature within the set fluctuation and uniformity range.
Applications
Measurement verification (standard mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermal resistance, standard copper-constantan Thermocouple), High Accuracy Heat and Cold Source Supply, Production and Scientific Research Experiments
Standards
The data did not mention specific compliance criteria
Steps
The information does not provide detailed operation steps
Notice
* Use the software digital lock function to avoid unrelated personnel operation.
Pay attention to the setting and status of the over-temperature protection alarm function.
* Ensure that the equipment is used within the specified Temperature range (-10~ 200 ℃).
Pay attention to the overheating and overcurrent protection status of the refrigeration system.