Overview
PINGXUAN Px-10300M-II standard verification High and low temperature Thermostatic bath is a High Accuracy temperature control equipment, mainly used for Measurement departments to verify the first and second standard mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermistor, standard copper-constantan Thermocouple, and can also be used as a High Accuracy heat source or cold source for production and scientific research.
Features
1. Adopt self-made temperature control technology developed by special software, cooperate with High Accuracy PT100 and all imported electronic components to ensure accurate control.
2. The software system supports temperature correction, with a resolution of up to 0.001 ° C to ensure accurate display temperature.
3. With over-temperature protection and alarm function, the alarm temperature can be set, and the load can be automatically cut off when the temperature is exceeded, which is safe and reliable.
4. Intelligent Software Temperature Stability, PID can automatically adjust the best parameters according to the medium, and also support manual adjustment.
5. The software digital locking function can lock various setting values to prevent unrelated personnel from misusing and ensure that the experimental data is correct.
6. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections for overheating and overcurrent.
7. Temperature range is wide (-10~ 300 ℃), Temperature Fluctuation and Uniformity are excellent, and the working tank volume is 6.5L.
Principle
The device uses dedicated software control technology, combined with a High Accuracy PT100 temperature sensor and imported electronic components, to monitor and adjust the temperature in the working tank in real time. The intelligent PID control system can automatically or manually adjust the control parameters according to different working media to achieve fast and stable temperature control. The refrigeration system is composed of a fully enclosed Compressor, which is responsible for rapid cooling, and the whole system has multiple safety protection mechanisms.
Applications
Measurement verification (standard mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermal resistance, standard copper-constantan Thermocouple), High Accuracy Heat and Cold Sources, Production and Scientific Research Experiments
Standards
The data did not mention specific compliance criteria
Steps
1. Connect the power supply and turn on the device.
2. Set the required temperature and over-temperature alarm temperature through the software system.
3. High Accuracy Temperature Correction can be performed using software as needed.
4. When the equipment is running, the intelligent PID system automatically or manually adjusts the parameters to quickly stabilize the temperature in the working tank.
5. After use, press the "Power" button to turn off all functions of the instrument.
Notice
• Before use, make sure that the equipment is well grounded and check whether the Power supply voltage meets the requirements.
• When setting the over-temperature alarm temperature, it should be set within a safe range to prevent equipment damage.
• Avoid non-professionals from operating or modifying the system settings locked by the software to ensure the accuracy of verification or experimental data.
• During the operation of the equipment, do not block the ventilating port to ensure that the cooling system dissipates heat normally.
• Regularly check the refrigeration system and electrical connections to ensure that the equipment is in good working condition.
Before moving or cleaning equipment, always cut off the power supply.