Overview
PINGXUAN Px-20300M-II standard verification High and low temperature Thermostatic bath is a High Accuracy temperature control equipment, mainly used for Measurement departments to verify first and second standard mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermistor, standard copper-Constantan Thermocouple, and can also be used as High Accuracy heat and cold sources for production and scientific research.
Features
1. Using dedicated software to develop self-made temperature control technology, equipped with High Accuracy PT100 and imported electronic components.
2. The software system supports temperature correction with resolution up to 0.001 ° C to ensure accurate display temperature.
3. With over-temperature protection, over-temperature tweet alarm function, can set the alarm temperature, over-temperature automatically cut off the load.
4. Intelligent Software Temperature Stability, PID can automatically adjust the best parameters according to the medium, and also support manual adjustment.
5. The software digitally locks the control system setting value to prevent unrelated personnel from misusing and ensure that the experimental data is correct.
6. Accurate temperature control allows for rapid and stable temperature in the working tank.
7. Equipped with an effective fully enclosed Compressor for refrigeration, with fast cooling speed and multiple protections for overheating and overcurrent.
8. Press the "Power" button to turn off all functions of the instrument.
Principle
The equipment uses a dedicated software control system, combined with a High Accuracy PT100 temperature sensor and imported electronic components, to accurately measure and adjust the temperature in the working tank. The intelligent PID algorithm can automatically or manually adjust the control parameters according to different working media to drive the heating or fully enclosed Compressor refrigeration system to achieve fast and stable temperature control, and has a perfect over-temperature protection mechanism.
Applications
Measurement verification, production, scientific research
Steps
1. Turn on the power supply.
2. Set the required temperature and over-temperature alarm temperature and other parameters through the software system.
3. Start the device, and the control system will automatically adjust the temperature according to the set parameters.
4. After the temperature in the working tank reaches the set value and stabilizes, verification or experimental operation can be carried out.
5. After use, press the "Power" button to turn off all functions.
Notice
• Please read the manual carefully before use to ensure correct operation.
• Set the over-temperature alarm temperature to ensure the safe operation of the equipment.
• Avoid unrelated personnel operation and use the software locking function to protect the set parameters.
• Pay attention to the working environment of the equipment and ensure that it is well ventilated.
• Regular maintenance inspections to ensure that the refrigeration system and protection functions are normal.