PINGXUAN Px-40300M-II standard verification High and low temperature Thermostatic bath is a High Accuracy temperature control equipment, mainly used for Measurement departments to verify the first and second standard mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermistor, standard copper-constantan Thermocouple, and can also be used as a High Accuracy heat source or cold source for production and scientific research.
Features
1. Using dedicated software to develop self-made temperature control technology, equipped with High Accuracy PT100 and all imported electronic components.
2. The software system supports temperature error correction, and the correction resolution is up to 0.001 ° C to ensure that the display temperature is accurate.
3. With over-temperature protection and alarm function, the alarm temperature can be set, and the load can be automatically cut off when the temperature is exceeded.
4. Intelligent Software Temperature Stability, PID can automatically adjust the best parameters according to different media, and also supports manual adjustment.
5. The software digitally locks the control system setting value to prevent unrelated personnel from misusing and ensure that the experimental data is correct.
6. Accurate temperature control allows for rapid and stable temperature in the working tank.
7. It uses an effective fully enclosed Compressor for cooling, with fast cooling speed and multiple protections for overheating and overcurrent.
8. Press the "Power" button to turn off all functions of the instrument.
Principle
The equipment drives the heating or cooling unit (fully enclosed Compressor) through a special software control system to precisely adjust the temperature of the medium in the working tank. The system monitors the temperature in real time through the High Accuracy PT100 Sensor, and automatically or manually adjusts the control parameters by the intelligent PID algorithm to achieve fast and stable temperature control, and has a perfect over-temperature protection mechanism.
Applications
Measurement verification (standard mercury-filledthermometer, BECKMAN thermometer, industrial platinum thermal resistance, standard copper-constantan Thermocouple), production, scientific research
Steps
1. Turn on the power supply.
2. Set the required temperature and over-temperature alarm temperature and other parameters through the software system.
3. Start the device, and the system will automatically or according to the set parameters for temperature control.
4. After use, press the "Power" button to turn off all functions.
Notice
* Avoid unrelated personnel operation and use the software lock function to protect the setting value.
* Pay attention to the over-temperature alarm setting to ensure that the device operates within a safe Temperature range.
* Follow the equipment environment requirements to ensure the normal cooling system.
Regularly check the accuracy of Sensors and Control Systems.