Overview
DK-8D three-hole three-temperature Thermostatic bath is equipped with three sets of independent sinks and corresponding temperature control devices. It can simultaneously set, control and display the temperature of the three sets of sinks at different temperatures, and realize 1-3 different temperatures of thermostatic test and auxiliary heating. It is widely used for drying, condensing, distillation, impregnation of chemical reagents, biological products, thermostatic fostering and boiling and disinfection of instruments.
Features
1. The three sets of thermostats are all microcomputer intelligent temperature control, with PID self-tuning, dual LED digital display and menu parameter setting functions.
2. With an independent temperature limit alarm system, over-temperature automatic alarm and power-off protection ensure experimental safety.
3. With 0-9999 minutes time setting function.
4. Accurate temperature control, easy operation and intuitive temperature indication.
5. The working water tank is made of stainless steel plate argon arc welding.
6. Cold rolled steel plate is used in the shell, and the surface is treated by electrostatic spraying, which is beautiful and elegant.
Principle
The device uses three independent microcomputer intelligent temperature control systems to PID adjust the heating elements in three independent sinks to achieve accurate temperature control. The system monitors the temperature of each sink in real time, and displays it through LED digital screens. When the temperature exceeds the set safety limit, the independent alarm system will start and automatically cut off the power supply to ensure safety.
Applications
Drying, condensing, distillation, impregnation of chemical reagents, impregnation of biological products, thermostatic fostering, equipment boiling and disinfection
Steps
1. Connect the 220V/50HZ power supply.
2. Add an appropriate amount of medium (e.g. water) to three separate sinks.
3. Through the microcomputer thermostat corresponding to each slot, set the required temperature and thermostatic time (0-9999 minutes).
4. Start the device, the system starts heating and automatically performs PID temperature control.
5. Observe the real-time temperature of each slot through the dual LED display.
6. After the experiment, turn off the power and clean the sink.
Notice
* Power supply voltage is 220V/50HZ before use.
* The device is equipped with an independent temperature limit alarm, please do not change or Shielding this function at will.
Please pay attention to safety during operation to prevent burns.
Keep the equipment clean and maintain it regularly.
Do not turn on the heating when there is no water or insufficient medium in the sink to avoid damage to the equipment.