Please contact customer service
Pneumatic clamping and foot switch, easy to operate and reduce errors. Measurement accuracy up to 0.01N, resolution 0.01N, stretching speed 1-399mm/min adjustable, equipped with 7-inch color touch screen real-time display data and Linear dispersion.
Category : Tensile Testing Machine
Brand : ZhiBang
SKU : NB033088
Service :The delivery and service By NBCLab.Com
Pneumatic vertical computer tension meter (model ZB-QL30) is an instrument specially designed for high-sensitivity and weak physical signal performance detection of Non-metallic materials such as paper and towels. It adopts a vertical single-column structure, is equipped with a pneumatic clamping device and a foot switch, which is easy to operate and can effectively reduce human error. The instrument is equipped with a high-speed microprocessor and a 7.0-inch color touch LCD screen, which can display test data and tensile curves in real time, and allows users to design experimental functions according to their needs.
1. Adopt imported motors for low noise and accurate control. 2. Adopt pneumatic blessing structure, equipped with foot switch, easy to operate and reduce operation error. 3. Adopt large-screen color touch LCD display, which can display various data and tensile curves in real time. 4. Measurement range of 0-30N, accuracy up to 0.01N, resolution 0.01N, professional measurement of the corresponding parameters of toilet paper. 5. Direct measurement results: After completing a set of tests, it is convenient to directly display measurement results and print statistical reports, including average value, standard deviation and coefficient of variation. 6. Variable sample size and tensile speed: For commonly used standard size samples, the tensile test can be carried out directly at the specified speed, and the appropriate tensile speed can be set as needed to change the test length and width of the sample. 7. Degree of automation: Instrument design uses professional devices at home and abroad, single-chip microcomputer for information sensing, data processing and action control, with automatic reset, data memory, overload protection. 8. Data communication: The instrument is equipped with a standard serial RS232 interface, which can provide data communication for the host computer comprehensive reporting system. 9. Measurement range: Measurement range can be changed according to user needs to configure different dynamometers, which can be widely used in tensile testing of various papers and materials. 10. Multifunctional, flexible configuration: The instrument is mainly used for paper measurement, and changing the configuration of the instrument can be widely applied to the measurement of other materials.
The instrument uses a pneumatic clamping structure to fix the sample and is driven by a motor to stretch. During the stretching process, the high-speed microprocessor chip collects real-time force and displacement data and processes them. The data and tensile curve are displayed in real time on the color touch LCD screen. When the sample is broken, the instrument automatically calculates and displays a number of physical parameters, and can perform statistical analysis on a set of test data.
Paper tension, tensile strength, elongation, fracture length, tensile energy absorption and other parameter measurement, food bag heat sealing strength, tensile strength, Peel Strength measurement, sanitary napkin adhesive strength, edge banding strength, tensile strength, elongation measurement, Pressure sensitive adhesive Peel Strength, tensile strength measurement, synthetic fiber filament breaking strength, elongation measurement, zipper slip measurement
ISO 1924 "Paper and Cardboard Determination of tensile strength", GB/T 12914 "Paper and Cardboard Determination of tensile strength", GB/T 24328.3 "Toilet paper and its products, Part 3: Determination of tensile strength, elongation at break and tensile energy absorption", GB/T 24328.4 "Toilet paper and its products, Part 4: Determination of wet tensile strength"
Connect the power supply (AC220V +/- 10% 50HZ). 2. According to the test requirements, adjust the sample holding distance within the range of 0-200mm. 3. Place the specimen between the pneumatic chucks. 4. Control the pneumatic device to clamp the sample through the foot switch. 5. Set or select the desired stretching speed (1 to 399 mm/min) on the touchscreen. 6. Start the test, the instrument automatically stretches and displays the data and Linear dispersion in real time. 7. After the sample is broken, the instrument automatically stops and displays the measurement results. 8. After completing a set of tests, you can view and print statistical reports (mean, standard deviation, coefficient of variation) by pressing the button. 9. After the test, the instrument can be automatically reset.
• Power supply voltage AC220V +/- 10%, frequency 50HZ. • The air source pressure needs to be kept within the range of 0.2Mpa to 0.4Mpa to ensure the stability of the clamping force. • According to the sample type and standard requirements, set the tensile speed and sample size reasonably. • Pay attention to safety during operation and avoid putting your hands or Miscellaneous items into the chuck area while the instrument is in operation. • The instrument should be placed on a stable workbench to avoid vibration affecting the test accuracy. • Regularly maintain and calibrate the instrument to ensure measurement Precision (indication Precision +/- 1%). • If you need to connect to the host computer, please use the standard RS232 interface for data communication.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.