Please contact customer service
It can perform various tests such as 90 ° disbonding, stretching, tearing, etc., with a capacity of 0-30kg, an accuracy of 0.5, an effective stretching space of 650mm, and supports customized fixtures to meet different sample requirements.
Category : Peel Strength Tester
Brand : JingHuaYiQi
SKU : NB033265
Service :The delivery and service By NBCLab.Com
90 ° Peel strength tester (model: LD-BL-A) is a professional equipment used to test the mechanical properties of materials such as disbonding and stretching. It is suitable for testing tensile strength and tensile strength of plastics, non-woven fabrics, leather, cloth zippers and other products. By configuring different fixtures, it can also be widely used in Coating, Plastic film, composite film, soft Encasement material, Adhesive, Adhesive tape, self-adhesive, rubber, paper and other materials. Tensile, elongation, tear, heat sealing strength and Peel Strength (such as 90 ° disbonding, 180 ° disbonding) and other items testing.
1. High Accuracy measurement: Using High Accuracy Sensor, the force value Measurement range is wide (0.02/100 -100%), the test force resolution is up to 250,000 yards, and the whole process resolution remains unchanged. 2. Wide range speed regulation: speed regulation range 0.01~ 500mm/min, speed accuracy +/- 0.5%, to meet a variety of standard test speed requirements. 3. Stable and reliable control system: using stepper motor and stepper drive control system, displacement Measurement accuracy within the indication of +/- 0.5%. 4. Flexible operation and safety protection: Support computer digital control and manual jog control test bench lifting, with software automatic diagnosis and electronic limit and other safety protection devices. 5. Customized fixtures: Special fixtures can be customized according to user product sample requirements, with wide applicability. 6. Convenient re-test: After the test, you can manually return to the initial position of the test at high speed or automatically.
The testing machine drives the transmission system through a stepper motor, so that the upper and lower grippers produce relative movement. During the test, the sample (such as adhesive tape) is clamped on the upper and lower clamps according to the standard method (such as folding 90 ° and peeling off a certain gluing surface) to ensure that the disbonding surface is consistent with the test machine force line. The machine performs continuous disbonding at a set constant speed (such as 300mm/min). The High Accuracy Sensor detects the force received during the disbonding process in real time, and the disbonding Linear dispersion is recorded and plotted by the system to calculate the performance parameters such as the Peel Strength of the material.
Plastic, Non-woven Fabric, Leather, Cloth Zipper, Coating, Plastic film, Composite film, Soft Encasement material, Adhesive, Adhesive tape, Self-adhesive, Rubber, paper
Adhesive tape disbonding test standard, ASTM D3330
1. Specimen preparation: Fold the free end of the sample in half by 90 degrees and peel off the gluing surface 25mm from the test plate. 2. Clamping the sample: Clamp the free end of the sample and the test plate on the upper and lower grippers respectively to ensure that the disbonding surface is consistent with the test machine line. 3. Setting parameters: Set the disbonding speed (e.g. 300mm/min +/- 10mm) according to the standard (e.g. GB/T2792). 4. Start the test: Start the testing machine for continuous disbonding, and the automatic recorder will draw the disbonding Linear dispersion. 5. Result calculation: In the distance range of 20-80mm after disbonding Linear dispersion, read a force value every 20mm, read at least 4 numbers, and then calculate the average value as the test result.
• When clamping the sample, make sure that the disbonding surface is consistent with the direction of the force line of the testing machine to ensure the accuracy of the test data. • Before testing, the sample should be strictly prepared according to relevant standards (such as GB/T2792), such as controlling the length of the peeled gluing surface. When setting the test speed, it must meet the range specified in the standard (e.g. 300mm/min +/- 10mm). • Result calculations should take values within a specified disbonding distance interval (e.g., 20-80mm) and average a sufficient number of readings. • Maintain and calibrate equipment regularly to ensure the accuracy of Sensors and measurement systems. • Pay attention to safety during operation, and use safety protection functions such as electronic limits and software diagnostics of the equipment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.