Please contact customer service
Infrared NDIR Sensor, detection accuracy ≤ +/- 3%, Response Time T90 ≤ 30 seconds. With IP65 Protection Rating, built-in pump suction measurement, sampling distance greater than 10 Meters, support simultaneous detection of 1-4 gases, standard 100,000 large-capacity data storage.
Category : Gas Detector
Brand : GaoPin
SKU : NB033428
Service :The delivery and service By NBCLab.Com
NGP40-CO2 portable multi-functional carbon dioxide detection and alarm instrument is an instrument for rapid detection of various gas concentrations, temperature and humidity measurement and excessive alarm. It uses 2.4 inch high definition color screen real-time display, selects well-known brand Sensor, based on electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photoion and other principles, can detect more than 1000 kinds of gases, suitable for pipeline, confined space, atmospheric environment gas concentration detection, leakage detection or high concentration single gas purity analysis.
1. Waterproof splash, dustproof, explosion-proof, shockproof, intrinsically safe circuit design, anti-static, anti-electromagnetic interference, Protection Rating IP65, built-in water vapor dust Filter. 2. Built-in pump suction measurement, Response fast, sampling distance > 10 meters, special gas path design can detect -0.5~ 2 kg positive and negative pressure gas. 3.2.4 inch high definition color screen display real-time concentration, alarm, time, temperature and humidity, storage, communication, power and other information. 4. Large-capacity data storage, standard 100,000, support real-time, timing or only store alarm data, can be uploaded through USB computer analysis. 5. USB charging interface, compatible with computer, power bank, mobile phone charger, with multiple protection, support hot swapping, can work when charging. 6. Using 4500mA large capacity polymer battery, long battery life. 7. Equipped with multi-directional three-dimensional alarm functions such as sound and light, vibration, vision, under-voltage, and fault. 8. The alarm value can be set, and the alarm mode can be selected as low alarm, high alarm, interval alarm, and weighted average alarm. 9. High Accuracy Temperature and Humidity measurement (optional), and temperature compensation for Sensor, Temperature range -40~ 70 ℃, can detect 400 ℃ gas (higher temperature can be customized). 10. It can simultaneously detect 1-4 kinds of gases, with free switching of units (e.g. PPM, mg/m ³, etc.). Conventional gases do not require input of molecular weight. 11. Three display modes can be switched: simultaneous display of four gases, large font circulation single channel, real-time Linear dispersion. 12. The Chinese and English interface is optional, and the default is Chinese. 13. With data recovery function, optional or full recovery is possible. 14. Zero automatic tracking, anti-zero drift. 15. The target point is calibrated three levels to ensure Linearity and accuracy, in line with national standards and local Measurement Bureau standards. 16. Automatic identification and prevention of concentration calibrating errors. 17. Supports real-time or timed detection, and the pump can be turned off to extend the startup time. 18. Can record calibrating, maintenance logs and fault countermeasures, with Sensor life expiration and next calibrating time reminder.
The instrument uses electrochemistry, infrared (NDIR), catalytic combustion, thermal conductivity, PID photoion and other Sensor principles for Gas detection. Through built-in pump sampling, the gas suction detection unit, Sensor generates corresponding signals according to the gas concentration, through professional circuit design and kernel algorithm processing, finally on the screen real-time display concentration value, and alarm according to the set threshold.
Chemical, Petroleum, Environmental Protection Flue Gas Analysis, Pipeline, Boiler Gas Analysis, Air Treatment and other occasions that need to detect gas concentration
Exia II CT4、IP65
1. Power on: Long press the power button to start the instrument. 2. Settings: Through the 5-button operation menu, language, alarm value, alarm mode, storage mode, etc. can be set. 3. Detection: The sampling probe is placed in the environment to be tested, and the instrument automatically pumps the sampling and displays the real-time concentration and temperature and humidity. 4. Data viewing: You can view historical data, Linear dispersion diagram on the machine, or connect to the computer through the USB interface to use the host computer software for analysis. 5. calibrate: follow the prompts to calibrate the target point three levels, the instrument will automatically identify and prevent misoperation. 6. Charging: Connect a charger, computer or power bank through the USB interface for charging, and support charging while using.
• This instrument is intrinsically safe explosion-proof equipment with explosion-proof mark Exia II CT4, please use it in the specified dangerous place. • Protection Rating is IP65, which can be dustproof and splash-proof, but non-diving equipment, do not immerse in liquids. • The environment temperature is -40 ° C~ + 70 ° C, and the sample gas Temperature range is the same; high temperature sampling and cooling filtrate handle is required to detect higher temperature gases. • The built-in Filter can be used in high humidity or high dust environment, and the Filter needs to be checked or replaced regularly. • Sensor life is generally 2-3 years, the instrument has a life expiration reminder function, please pay attention and replace it in time. • The battery has overcharge, overdischarge, overvoltage, overheating, and short circuit protection. Please use a matching or compatible charging device. • When calibrating, make sure to use standard gas and follow the operation prompts to avoid misoperation. • When not tested for a long time, the pump can be turned off to save power and prolong the use time of the instrument. • The function of storing data is turned off by default. If you want to use it, please turn it on in the settings and set the storage interval. • Optional accessories (such as temperature and humidity function, telescopic sampling handle, etc.) can be customized according to actual needs to expand the application range.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.