Please contact customer service
Adopt ALLHEAT cavity preheating and S. H-Transfer shelf heat transfer technology to ensure uniform temperature distribution with a fluctuation of +/- 0.5 ° C. Equipped with microcomputer PID control, programmable ten-stage temperature, vacuum range 0-999.9mb, and multiple safety protections.
Category : Drying Oven
Brand : Kenton
SKU : NB033586
Service :The delivery and service By NBCLab.Com
Kenton KZ-50 LCD screen Vacuum oven is specially designed for drying heat-sensitive and prone to oxidation substances, especially suitable for powder or granular samples, which can effectively shorten the drying time. It uses ALLHEAT ™ cavity preheating technology, S. H-Transfer ™ shelf heat transfer technology and microcomputer PID control to ensure uniform temperature distribution in the cavity and ensure the smooth progress of the experiment. The product has passed the European Union CE safety certification, complies with the Australian AS/NZS3350 standard, and provides a variety of verification services.
1. Using ALLHEAT ™ cavity preheating technology, the heating elements are evenly distributed, combined with heat transfer and forced fan convection to ensure uniform temperature distribution in the cavity and low energy consumption. 2. Equipped with ALLSENS ™ microcomputer PID control technology, integrated LCD dot matrix large-screen LCD display (Chinese/English optional), adaptive PID program control, accurate temperature control, to prevent temperature overshoot. 3. Using Pro-Insulation ™ insulation technology, liner and shell are completely isolated design, with high density imported insulation materials, effective insulation. 4. Using the original imported industrial grade PT100 temperature sensor, Response is fast, self-heating effect is small. 5. Ergonomic Structure Design, Arc Appearance, External Door and LCD Panel Integration, Movable Mesh Shelf Adjustable, Easy to Observe and Operate. 6. The liner is made of SUS304 stainless steel, with a circular arc design around it. Shelf can be extracted for easy cleaning and maintenance. 7. Electrical control components are centrally installed on the upper part of the box for easy maintenance; the LCD controller has a diagnostic function and can display historical operation data. 8. With multiple safety protection: abnormal parameter sound and light alarm, automatic double temperature protection, explosion-proof tempered Glass observation window, shatterproof safety Glass panel, etc. 9. User password control, standard RS485 interface, can connect multiple devices for real-time monitoring; optional ALLSENS ™ programmable software for remote control. 10. Can provide Chinese/English IQ, OQ, PQ and a variety of verification services.
The Vacuum oven reduces the pressure in the working chamber to the set vacuum range (absolute pressure 0~ 999.9mb) through the Vacuumpump, thereby reducing the boiling point of the solvent in the sample and accelerating the evaporation of water or solvent. At the same time, the ALLHEAT ™ technology is used to uniformly preheat the inner cavity, and the heat transfer through the S. H-Transfer ™ shelf and forced convection of the fan make the heat evenly transferred to the sample. The microcomputer PID control system precisely adjusts the Heating power to maintain the constant set temperature in the cavity, and realizes efficient and uniform drying of heat-sensitive and easy oxidation substances in low temperature and low oxygen environment.
Biology, business, agricultural research
European Union CE safety certification, Australian AS/NZS3350 standard, German DIN 12880 Class 3.1 standard, international IEC 61010-1 standard, American UL 61010-1 standard, European Union EN 61010-1 standard
1. Place the sample: Place the sample on the movable mesh shelf, and the shelf spacing can be adjusted according to needs. 2. Close the box door: make sure the door is well sealed and lock it with the door handle with the fastening device. 3. Setting parameters: Set the required temperature, vacuum, running time and other parameters through the LCD touch screen. 4. Start operation: After confirming the parameters, start the equipment, and the equipment will automatically execute the vacuuming and heating procedures. 5. Process monitoring: Temperature, wind speed, running time, etc. can be monitored in real time through the LCD screen, or remotely monitored by connecting to a computer through the RS485 interface. 6. Finish taking out: After the run is over, the system prompts. After the chamber returns to normal pressure and chills down, open the box door to take out the sample.
* The equipment should be used under the conditions of working environment temperature RT + 10~ 30 ℃, humidity below 70%, voltage fluctuation +/- 10%. Do not force open the box door in a vacuum. When placing the sample, do not block the inner cavity air duct to ensure uniform temperature. * When cleaning the liner, please use a soft cloth to wipe and avoid using corrosive cleaners. Before performing maintenance, be sure to disconnect the power supply of the equipment. * If there is an abnormal alarm, please check and troubleshoot according to the prompt information before using it. All technical data were measured under no-load conditions, and actual use may vary depending on sample loading.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.