Overview
HUXI HTS-X330 Decolorization Shaker is a laboratory oscillation treatment equipment, divided into heated and unheated series. It is widely used in Electrophoresis gel fixation, Coomassie blue staining decolorization, silver nitrate (AgNO3) staining, radiological self-Development experiments, molecular hybridization, cell fostering and other experimental scenarios. It can be used in low temperature and Thermal Chambers. The heating series integrates oscillation and heating functions to meet the experimental needs of both heating and opening.
Features
1. Large LCD display timing time and Rotation speed, Operating interface is easy to understand
2. Locked operation mode to prevent misoperation
3. DC brushless motor drive, low noise, accurate speed, long service life, maintenance-free
4. Soft start function, accelerate evenly, effectively avoid sample splashing
5. Molded natural rubber platform, acid and alkali corrosion resistance, easy to clean
6. Optional RS232 interface, connected to the computer to achieve parameter setting and real-time display of Linear dispersion
7. Heating series Heating fast, Temperature range, up to 100 ℃ above, fill the gap that Shaker can not operate at high temperature
Principle
The decolorized Shaker is driven by a brushless DC motor and adopts a rotary oscillation mode. The pendulum amplitude is 8mm, and the Oscillation Frequency range is 60~ 400rpm (optional to 500rpm). The equipment achieves uniform acceleration through soft start to avoid sample splashing, while the molded natural rubber platform provides a stable oscillating surface.
Applications
Electrophoresis gel fixation, Coomassie blue staining decolorization, silver nitrate (AgNO3) staining fixation, silver nitrate (AgNO3) staining, silver nitrate (AgNO3) staining Development, X-ray negative development, X-ray negative fixation, cellulose membrane treatment after electrophoresis transfer, molecular hybridization, antigenome reaction, antigenome staining, cell foster, cell membrane transfer
Steps
1. Connect the power supply (100~ 240V, 50/60Hz)
2. Set the timing time (up to 99 hours and 59 minutes) and Rotation speed (60~ 400rpm) through the large screen LCD interface
3. Place the sample (maximum load 7.5kg)
4. Start the device and the soft start function starts to work
5. For heating function, set the heating temperature (only heating series)
6. Optional RS232 interface to connect to computer for parameter monitoring
Notice
• Ambient Temperature should be kept within 5~ 40 ℃
• environment relative humidity shall not exceed 80%
• The maximum load weight is 7.5kg, please do not overload
• Clean the natural rubber platform in time after use
• Pay attention to the high temperature surface when using the heating series to avoid burns
• The device has a locked operation mode, please do not force the operation