Please contact customer service
Proportional monitoring dual beam of light and Holographic grating monochromator, Light spectrum Bandwidth 1.8nm, stray light ≤ 0.05%, with 8-inch touch screen and automatic 8-cell Colorimetric dish holder, easy to operate and reliable data.
Category : Spectrophotometer
Brand : ShangFen
SKU : NB035525
Service :The delivery and service By NBCLab.Com
The L3S visible spectrophotometer uses a professional proportional monitoring dual beam of light optical path system and low noise circuit design, with excellent Reliability and Stability, which can meet the needs of a variety of applications from daily analysis to scientific research.
1. Adopt professional optical, mechanical and electrical design, stable performance and high cost performance. 2. Equipped with an 8-inch color touch LCD display, it is flexible and convenient to operate. 3. Adopt proportional monitoring double beam of light optical path structure, configure high performance blazing Holographic grating monochromator, Optical inspection accuracy, measurement accuracy, reproducibility and Stability. 4. With unique automatic adjustment "0%" and "100%" functions, as well as automatic 8-pool Colorimetric dish holder. 5. Support full-band scanning (limited to S type), sub-band scanning (limited to S type), dynamic time scanning, GOTO lambda, linear regression, concentration direct reading, peak and valley detection and other advanced functions. 6. Optional thermal plotter for data printing, Light spectrum scanning (limited to S type), fixed wavelength time scanning, linear regression and other Linear dispersion drawing. 7. Equipped with USB interface, it can interact with PC, strengthen data processing and graph management functions, support mass storage, and facilitate user secondary development. 8. Equipped with professional power-off protection measures, it can memorize test data, scan patterns, regression equations, and instrument correction values. It can be quickly initialized to enter the test state after startup.
The instrument uses a proportional monitoring dual beam of light optical path system. After the light emitted by the light source is split by the monochromator, monochromatic light is formed. The beam of light is divided into the sample beam of light and the reference beam of light, which pass through the sample cell and the reference cell respectively. The Detector monitors the light intensity of the two beams of light synchronously, and eliminates the influence of light source fluctuations and other factors through proportional calculation, so as to accurately determine the transmittance or Absorbance of the sample.
Daily analysis, scientific research
1. Turn it on and warm up. 2. According to the test requirements, set parameters such as wavelength through the touch screen. 3. Use the automatic adjustment function to calibrate "0%" and "100%". 4. Put the sample to be tested and the reference solution into the automatic 8-cell Colorimetric dish holder. 5. Select the desired Measurement mode (such as concentration direct reading, Light spectrum scanning, etc.) and start the test. 6. View the data through the screen, or export the data to the PC through the USB interface for further processing. 7. Optional thermal plotter for data or graph printing.
• The instrument should be placed in a stable, no strong vibration, avoid direct sunlight environment. • Power supply voltage AC220V +/- 22V, frequency in the range of 50Hz +/- 1Hz. • Preheating and stabilization are required after startup to obtain the best Measurement accuracy. • Colorimetric dishes should be cleaned before and after use to avoid contamination affecting the measurement results. • When performing advanced functions such as Light spectrum scanning, please confirm that the instrument is an S model. • Optional accessories such as thermal graphics printer or UVwin8 Light spectrum software need to be configured separately. • The instrument comes standard with a 1cm Colorimetric dish rack, and Miscellaneous specifications need to be selected. • Note that the light source is an imported tungsten halogen lamp, which may need to be replaced after long-term use. • The instrument has a power-off protection function, but do not suddenly power off unless necessary.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.